Registration Dossier

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
25.10.2012 to 06.11.2012
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2012
Report Date:
2012

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
other:
Principles of method if other than guideline:
Measurement of relative amounts of particles present, sorted according to size
GLP compliance:
no
Type of distribution:
counted distribution

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
solid: crystalline
Details on test material:
-Name of test material : 4-fluorophenol
- Molecular formula : C6H5FO
- Substance type: Organic
- Physical state: Solid

Results and discussion

Particle size
Percentile:
D50
Remarks on result:
other: Migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.
Particle size distribution at different passages
No.:
#1
Size:
1 000 µm
Distribution:
100 %

Applicant's summary and conclusion

Conclusions:
4-fluorophenol was found to have a uniform particle size of 1000 micrometer when analyzed by the particle size distribution method.

Executive summary: