Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
31-07-2018 – 31-07-2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Justification for type of information:
Experimental test result performed using standard test guidelines
Qualifier:
according to
Guideline:
other: OECD 103
Principles of method if other than guideline:
The flash point determination of Test item Ferrate(4-), hexakis(cyano-C)-, Et 2-[6-(ethylamino)-3-(ethylimino)-2,7-dimethyl-3H-xanthen-9-yl]benzoate copper(2+) salts (CAS No. 12237-63-7 )was done. The method was closed cup method using Pensky-Martens Flash Point Apparatus.
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Specific details on test material used for the study:
- Common name: C.I. Pigment Red 169
- Molecular formula: C28H30CuFeN2O3
- SMILEY: CCc1cccc(c1C(=O)O)c2c3cc(c(cc3oc-4c/c(=N\CC)/c(cc24)C)NCC)C.[Fe].[Cu]
- InChi: 1S/C28H30N2O3.Cu.Fe/c1-6-18-10-9-11-19(26(18)28(31)32)27-20-12-16(4)22(29-7-2)14-24(20)33-25-15-23(30-8-3)17(5)13-21(25)27;;/h9-15,29H,6-8H2,1-5H3,(H,31,32);;/b30-23+;;
- Substance type: Organic
- Physical state: Solid
Key result
Flash point:
188.6 °C
Atm. press.:
967.3 hPa
Remarks on result:
other: No other detail available

Method Details  Observations  Remarks if, any
 Method  Closed cup method                         

Principle of Flash point

test

The flash point of a flammable

liquid is the lowest temperature at

which there will be enough

flammable vapor to ignite when an

ignition source is applied.

 
 
 Type of method  Closed cup  
 Flash point apparatus  
  • Abel’s flash pt apparatus
  • Pensky-Martens flash point apparatus

 Pensky-Martens flash

point apparatus

Quantity of chemical

used

 g/ml

 5.002

 Ignition source

 Gas lighter/flame

 Gas lighter

Atmospheric pressure 

 hPa

 967.3hPa

 flash pointFlash point

(RESULT)

 °C

 188.6°C

Interpretation of results:
GHS criteria not met
Conclusions:
The flash point determination of Test item Ferrate(4-), hexakis(cyano-C)-, Et 2-[6-(ethylamino)-3-(ethylimino)-2,7-dimethyl-3H-xanthen-9-yl]benzoate copper(2+) salts (CAS No. 12237-63-7 )was done. The method was closed cup method using Pensky-Martens Flash Point Apparatus. The meanflash point of the test item was determine to be 188.6°C at 967.3 hPa.
Executive summary:

The flash point determination of Test item Ferrate(4-), hexakis(cyano-C)-, Et 2 -[6 -(ethylamino)-3 -(ethylimino)-2,7 -dimethyl-3H-xanthen-9 -yl]benzoate copper(2 +) salts (CAS No. 12237 -63 -7 )was done. The method was closed cup method using Pensky-Martens Flash Point Apparatus. The mean flash point of the test item was determine to be 188.6°C at 967.3 hPa.

Description of key information

The flash point determination of Test item Ferrate(4-), hexakis(cyano-C)-, Et 2 -[6 -(ethylamino)-3 -(ethylimino)-2,7 -dimethyl-3H-xanthen-9 -yl]benzoate copper(2 +) salts (CAS No. 12237 -63 -7 )was done. The method was closed cup method using Pensky-Martens Flash Point Apparatus. The mean flash point of the test item was determine to be 188.6°C at 967.3 hPa.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
188.6 °C

Additional information

The flash point determination of Test item Ferrate(4-), hexakis(cyano-C)-, Et 2 -[6 -(ethylamino)-3 -(ethylimino)-2,7 -dimethyl-3H-xanthen-9 -yl]benzoate copper(2 +) salts (CAS No. 12237 -63 -7 )was done. The method was closed cup method using Pensky-Martens Flash Point Apparatus. The mean flash point of the test item was determine to be 188.6°C at 967.3 hPa.

From other reliable sources flash point of ferrate(4 -), hexakis(cyano-C)-, Et 2 -[6 -(ethylamino)-3 -(ethylimino)-2,7 -dimethyl-3H-xanthen-9 -yl]benzoate copper(2 +) salts(Pigment red 169) was expected to be above 200°C