Registration Dossier

Administrative data

Endpoint:
stability: thermal, sunlight, metals, other
Remarks:
Migrated from section 'Stability: thermal, sunlight, metals'
Type of information:
experimental study
Adequacy of study:
supporting study
Reliability:
4 (not assignable)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1989
Report Date:
1988

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
other: DIN 51007
GLP compliance:
no

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
Name of test material (as cited in study report): 1,3-Diaminopropan
Analytical purity: not specified

Results and discussion

For thermal stability study

Test substance thermally stable:
yes
Operating temperature
Operating temp.:
30 - 500 °C
Remarks on result:
other: exothemic reaction: 450 J/g at onset temperatue 340°C

Any other information on results incl. tables

DSC:   Differential Scanning Calorimetry (DSC) according to DIN 51007
             
Test Parameters          
Apparatus:   Mettler TA 3000/4000/ 8000           
Sample containers: closed high pressure cell made of V2A    
Sample weight:  no data        
Reference material: empty container           
Heating rate:    2 K/min        
Temperature range: from 30 °C to 500 'C      
             
Results            
1'' reaction:    exothermic            
 Onset temperature:   340 °C  
Peak temperature:  400 °C        
Energy release:  450 J/g        

Applicant's summary and conclusion