Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Surface tension

Currently viewing:

Administrative data

Endpoint:
surface tension
Type of information:
experimental study
Adequacy of study:
supporting study
Study period:
2010
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
comparable to guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report date:
2010

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: ASTM D1331
Deviations:
no
Principles of method if other than guideline:
None
GLP compliance:
no
Remarks:
GLP study not necessary here.
Type of method:
ring method

Test material

Constituent 1
Chemical structure
Reference substance name:
Zinc bis[O-(2-ethylhexyl)] bis[O-(isobutyl)] bis(dithiophosphate)
EC Number:
247-810-2
EC Name:
Zinc bis[O-(2-ethylhexyl)] bis[O-(isobutyl)] bis(dithiophosphate)
Cas Number:
26566-95-0
Molecular formula:
C12H27O2PS2.1/2Zn
IUPAC Name:
Zinc, bis[O-(2-ethylhexyl) O-(2-methylpropyl) phosphorodithioato-κS,κS']-, (T-4)-
Details on test material:
- Expiration date: December 31, 2010

Results and discussion

Surface tension
Remarks on result:
other: Test method could not be run in a ventillation hood because the apparatus would be unable to equilibrate.

Any other information on results incl. tables

None

Applicant's summary and conclusion

Conclusions:
Test apparatus could not be equilibrated in ventillation hood, which was required due to the toxic nature of the test material.
Executive summary:

Test apparatus could not be equilibrated in ventillation hood, which was required due to the toxic nature of the test material.