Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
acute toxicity: other routes
Type of information:
experimental study
Adequacy of study:
other information
Study period:
1963
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: No GLP, no guideline followed, not enough data to complete a full IUCLID record.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1963
Report date:
1963

Materials and methods

Test guideline
Qualifier:
no guideline available
GLP compliance:
no
Limit test:
yes

Test material

Constituent 1
Chemical structure
Reference substance name:
N,N-bis(3-aminopropyl)methylamine
EC Number:
203-336-8
EC Name:
N,N-bis(3-aminopropyl)methylamine
Cas Number:
105-83-9
Molecular formula:
C7H19N3
IUPAC Name:
bis(3-aminopropyl)(methyl)amine
Details on test material:
- Name of the test substance: Bis-(3-aminopropyl-9methylamine, no further data.

Test animals

Species:
mouse
Strain:
not specified
Sex:
not specified

Administration / exposure

Route of administration:
intraperitoneal
Vehicle:
water
Doses:
The mice were applied with 21 5 solution of teh test substance
No. of animals per sex per dose:
No data
Control animals:
not specified

Results and discussion

Effect levelsopen allclose all
Sex:
not specified
Dose descriptor:
LD50
Effect level:
90 other: mm³
Based on:
test mat.
Remarks on result:
other: Equivalent to 0.09 mL/kg bw, obtained in mice with pH 11 21 % test solution.
Sex:
not specified
Dose descriptor:
LD50
Effect level:
450 other: mm³
Remarks on result:
other: quivalent to 0.45 mL/kg bw, obtained in mice with pH 7 21 % test solution

Any other information on results incl. tables

Symptoms observed: agitation, staggering, shortness of breath, cramps

In autopsy: following application of teh basic test substance solution, corrosion of the peritoneaum was observed.

Applicant's summary and conclusion