Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Environmental fate & pathways

Endpoint summary

Administrative data

Description of key information

Bioaccumulation: aquatic / sediment

The bioaccumulation study was conducted for estimating the BCF (bioaccumulation factor) value of test chemical (authoritative databases, 2017). The bioaccumulation factor (BCF) value was calculated using a logKow of 1.41 and a regression-derived equation. The estimated BCF (bioaccumulation factor) valueof test chemical was determined to be 3.0 dimensionless, which does not exceed the bioconcentration threshold of 2000, indicating that the test chemical is considered to be non-accumulative in aquatic organisms.

Additional information

Bioaccumulation: aquatic / sediment

Various predicted data of the test chemical were reviewed for the bioaccumulation end point which are summarized as below:

 

In a weight of evidence study from authoritative databases (2017), the bioaccumulation experiment was conducted for estimating the BCF (bioaccumulation factor) value of test chemical. The bioaccumulation factor (BCF) value was calculated using a logKow of 1.41 and a regression-derived equation. The estimated BCF (bioaccumulation factor) valueoftest chemicalwas determined to be 3.0 dimensionless.

 

In a prediction done using the BCFBAF Program of Estimation Programs Interface was used to predict the bioconcentration factor (BCF) of test chemical. The bioconcentration factor (BCF) of test chemical was estimated to be 3.162 L/kg whole body w.w (at 25 deg C).

 

From CompTox Chemistry Dashboard using OPERA (OPEn (quantitative) structure-activity Relationship Application)  V1.02 model in which calculation based on PaDEL descriptors (calculate molecular descriptors and fingerprints of chemical), the bioaccumulation i.e BCF for test chemical was estimated to be 3.54 dimensionless . The predicted BCF result based on the 5 OECD principles.

 

On the basis of above results for test chemical, it can be concluded that the BCF value of test chemical was estimated to be ranges from 3.0 to 3.54 respectively,which does not exceeds the bioconcentration threshold of 2000, indicating that the test chemical is not expected to bioaccumulate in the food chain.

 

Bioaccumulation endpoint can also be considered for waiver as per inaccordance with column 2 of Annex IX of the REACH regulation, testing for this endpoint is scientifically not necessary and does not need to be conducted since the test chemical has a low potential for bioaccumulation based on logKow ≤ 3.