Registration Dossier

Administrative data

First-aid measures

INHALATION
Remove to fresh air and rest. Rinse nose, mouth and throat with water.
SKIN CONTACT
Remove contaminated clothing. Wash skin with soap and plenty of water.
EYE CONTACT
Flush immediately with plenty of water for at least 15 minutes and seek medical attention.
INGESTION
Wash out mouth with water. Never give anything by mouth to an unconcious person. Seek medical attention.


Fire-fighting measures

EXTINGUISHING MEDIA
Water spray, foam, dry powder or carbon dioxide.
SPECIAL FIRE FIGHTING PROCEDURES
Wear self-contained breathing apparatus and protective clothing against toxic fumes.
FIRE & EXPLOSION HAZARDS
Emits toxic iodine fumes under fire conditions.

Accidental release measures

STEPS TO BE TAKEN IN CASE MATERIAL IS SPILLED OR RELEASED
Avoid raising dust. Place dry spillage in appropriate container for waste disposals.
CLEANING METHODS
Wash premises, equipment and working surfaces with water. Avoid water reach superficial or municipal system flow
WASTE DISPOSALS METHODS
Dispose of waste in authorized plant, in accordance with the applicable local and nacional laws



Handling and storage

HANDLING
Avoid inhalation of dust and direct skin contact. Avoid electrostatic charge formation conditions. Provide for adequate ventilation (local exhaust or laboratory fume hood). Keep away from ignition sources and hot surfaces
STORAGE
Keep in tightly closed containers in a fresh, dry and ventilated area. Store under normal indoor storing conditions. Provide adequate ventilation. Avoid heat and light
STABILITY
The compound is stable at room temperatures.



Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (IMDG)

Remarksopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

OCCUPATIONAL EXPOSURE LIMITS
No exposure limits are established for the substance.
VENTILATION
Local exhaust must be needed
PERSONAL PROTECTIVE EQUIPMENT
Wear suitable protective clothing, protective goggles and gloves. Respiratory protection with dust
filter P2. Provide eye-wash facilities and safety shower.

Stability and reactivity

STABILITY
The compound is stable at room temperatures.
CONDITIONS TO AVOID
Heat may decompose the substance. Thermal decomposition produces iodine fumes
MATERIALS TO AVOID
Caustic agents.

Disposal considerations

Collect the dry waste in closed and labelled containers
Dispose of waste in authorized plant, in accordance with the applicable local and national laws.