Registration Dossier

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Acceptable, well documented study report which meets basic scientific principles

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2012
Report Date:
2012

Materials and methods

Test guideline
Qualifier:
no guideline followed
Principles of method if other than guideline:
The size distribution of the suspended particles was determined by laser diffraction method.
GLP compliance:
no
Type of distribution:
volumetric distribution

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Particle sizeopen allclose all
Percentile:
D50
Remarks on result:
other: Migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.
Percentile:
D10
Mean:
14.96 µm
St. dev.:
0
Percentile:
D50
Mean:
59.95 µm
St. dev.:
0
Percentile:
D90
Mean:
226.4 µm
St. dev.:
0

Applicant's summary and conclusion