Registration Dossier

Administrative data

Link to relevant study record(s)

Description of key information

The flammability of 1,3-diphenyl-2-thiourea (DPTU)  was performed in a study performed in accordance with EC regulation 440/2008 EC A 10 method. The shortest burning time observed was 79s.
The 1,3-diphenyl-2-thiourea (DPTU) was not considered as highly flammable under our experimental conditions.

Key value for chemical safety assessment

Flammability:
non flammable

Additional information

The flammability of 1,3-diphenyl-2-thiourea (DPTU) was performed in a study performed in accordance with EC regulation 440/2008 EC A 10 method.

The 1,3-diphenyl-2-thiourea (DPTU) was not considered as highly flammable under our experimental conditions.

Justification for classification or non-classification

The flammability of DPTU was performed in accordance with EC regulation 440/2008 EC A 10 method. A preliminary test and a main test were performed. DPTU was not considered as highly flammable under our experimental conditions.