Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
19 July 2011
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Certificate of Analysis
Qualifier:
according to guideline
Guideline:
ISO No., other: Petroleum products-Determination of flash and fire point - Cleveland open cup method
Qualifier:
according to guideline
Guideline:
ISO No., other: Standard Test Method for Flash und Fire Points by Cleveland Open Cup - ASTM D92-97
Qualifier:
according to guideline
Guideline:
ISO No., other: Determination of open flash and fire point - Cleveland method -IP 36/84 (1989)
GLP compliance:
no
Type of method:
open cup
Flash point:
159 °C
Atm. press.:
1 013 hPa

Description of key information

159 °C at 1013 hPa (Cleveland Open Cup method)

Key value for chemical safety assessment

Flash point at 101 325 Pa:
159 °C

Additional information