Registration Dossier

Administrative data

First-aid measures

4.1. Description of first aid measures
Remove contaminated clothing.

If inhaled:
Keep patient calm, remove to fresh air.

On skin contact:
Wash thoroughly with soap and water.

On contact with eyes:
Wash affected eyes for at least 15 minutes under running water with eyelids held open.

On ingestion:
Rinse mouth and then drink plenty of water.

4.2. Most important symptoms and effects, both acute and delayed
Symptoms: The most important known symptoms and effects are described in the labelling (see section 2) and/or in section 11., Further symptoms are possible

4.3. Indication of any immediate medical attention and special treatment needed
Treatment: Symptomatic treatment (decontamination, vital functions).

Fire-fighting measures

5.1. Extinguishing media
Suitable extinguishing media:
water spray, dry powder, foam, carbon dioxide

5.2. Special hazards arising from the substance or mixture
nitrogen oxides, carbon oxides
The substances/groups of substances mentioned can be released in case of fire. Under certain conditions in case of fire other hazardous combustion products may be generated.

5.3. Advice for fire-fighters
Special protective equipment:
Wear self-contained breathing apparatus and chemical-protective clothing.

Further information:
Dispose of fire debris and contaminated extinguishing water in accordance with official regulations.

Accidental release measures

6.1. Personal precautions, protective equipment and emergency procedures
Avoid inhalation. Avoid contact with the skin, eyes and clothing.

6.2. Environmental precautions
Do not discharge into drains/surface waters/groundwater.

6.3. Methods and material for containment and cleaning up
For large amounts: Pump off product.
For residues: Pick up with suitable absorbent material (e.g. sand, sawdust, general-purpose binder, kieselguhr). Dispose of absorbed material in accordance with regulations.

6.4. Reference to other sections
Information regarding exposure controls/personal protection and disposal considerations can be found in section 8 and 13.

Handling and storage

7.1. Precautions for safe handling
Ensure thorough ventilation of stores and work areas. Handle in accordance with good industrial hygiene and safety practice. When using do not eat, drink or smoke. Hands and/or face should be washed before breaks and at the end of the shift.

Protection against fire and explosion:
Prevent electrostatic charge - sources of ignition should be kept well clear - fire extinguishers should be kept handy.

7.2. Conditions for safe storage, including any incompatibilities
Segregate from acids and acid forming substances.
Further information on storage conditions: Containers should be stored tightly sealed in a dry place.

Storage stability:
Storage duration: 24 Months
From the data on storage duration in this safety data sheet no agreed statement regarding the warrantee of application properties can be deduced.

7.3. Specific end use(s)
For the relevant identified use(s) listed in Section 1 the advice mentioned in this section 7 is to be observed.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (IMDG)

Remarksopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

8.1. Control parameters

Components with occupational exposure limits

No occupational exposure limits known.

PNEC
freshwater: 0.2 mg/l

marine water: 0.02 mg/l

intermittent release: 1 mg/l

STP: 97 mg/l

sediment (freshwater): 648 mg/kg

sediment (marine water): 64.8 mg/kg

soil: 0.78 mg/kg


DNEL
worker:
Long-term exposure- systemic effects, dermal: 0.13 mg/kg

worker:
Long-term exposure- systemic effects, Inhalation: 0.23 mg/m3


8.2. Exposure controls
Personal protective equipment
Respiratory protection:
Respiratory protection in case of vapour/aerosol release. Gas filter for gases/vapours of organic compounds (boiling point >65 °C, e. g. EN 14387 Type A)

Hand protection:
Suitable materials also with prolonged, direct contact (Recommended: Protective index 6, corresponding > 480 minutes of permeation time according to EN 374):
fluoroelastomer (FKM) - 0.7 mm coating thickness
Supplementary note: The specifications are based on tests, literature data and information of glove manufacturers or are derived from similar substances by analogy. Due to many conditions (e.g. temperature) it must be considered, that the practical usage of a chemical-protective glove in practice may be much shorter than the permeation time determined through testing.
Manufacturer's directions for use should be observed because of great diversity of types.

Eye protection:
Safety glasses with side-shields (frame goggles) (e.g. EN 166)

Body protection:
Body protection must be chosen depending on activity and possible exposure, e.g. apron, protecting boots, chemical-protection suit (according to EN 14605 in case of splashes or EN ISO 13982 in case of dust).

General safety and hygiene measures
Handle in accordance with good industrial hygiene and safety practice. Females of childbearing age should not come into contact with the product. Wearing of closed work clothing is required additionally to the stated personal protection equipment. Take off immediately all contaminated clothing. Store work clothing separately.

Stability and reactivity

10.1. Reactivity
No hazardous reactions if stored and handled as prescribed/indicated.


Corrosion to metals:
Corrosive effects to metal are not anticipated.
Formation of flammable gases: Remarks: Forms no flammable gases in the presence of water.


10.2. Chemical stability
The product is stable if stored and handled as prescribed/indicated.

10.3. Possibility of hazardous reactions
Evolution of heat under influence of acids.


10.4. Conditions to avoid
Avoid extreme heat.

10.5. Incompatible materials

Substances to avoid:
acids, acid forming substances, nitrosating agents

10.6. Hazardous decomposition products

Possible thermal decomposition products:
carbon oxides, nitrogen oxides

Disposal considerations

13.1. Waste treatment methods

Incinerate in suitable incineration plant, observing local authority regulations.

A waste code in accordance with the European waste catalog (EWC) cannot be specified, due to dependence on the usage.
The waste code in accordance with the European waste catalog (EWC) must be specified in cooperation with disposal agency/manufacturer/authorities.


Contaminated packaging:
Contaminated packaging should be emptied as far as possible; then it can be passed on for recycling after being thoroughly cleaned.