Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
29 April - 25 July, 2008
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: The study has been performed according to OECD and/or EC guidelines and according to GLP principles.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2008
Report date:
2008

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup

Test material

Constituent 1
Chemical structure
Reference substance name:
1-Propanone, 2-hydroxy-2-methyl-, 1-(4-C10-13-alkylphenyl) derivs.
Cas Number:
1001416-18-7
Molecular formula:
Not applicable - UVCB
IUPAC Name:
1-Propanone, 2-hydroxy-2-methyl-, 1-(4-C10-13-alkylphenyl) derivs.

Results and discussion

Flash point
Flash point:
157 °C
Atm. press.:
100.3 kPa

Applicant's summary and conclusion

Conclusions:
The Pensky-Martens closed cup method was applied for the determination of the flash-point of the substance. The flash-point of the test substance was 157°C.
Executive summary:

The flash point of the substance was determioned accoerding to EU method A.9. The Pensky-Martens closed cup method was applied for the determination of the flash-point of the substance. The flash-point of the test substance was 157 °C.