Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
21 February 2012
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Data are sufficient and scientifically acceptable.
Qualifier:
no guideline followed
Principles of method if other than guideline:
Method used was laser diffraction. The technique of laser diffraction is based on the principle that particles passing through a laser beam will scatter light at an angle that is directly related to their size: large particles scatter at low angles, whereas small particles scatter at high angles. The method is standardized [ISO 13320-1: 1999 Particle size analysis - Laser diffraction methods - Part 1: General principles].
GLP compliance:
not specified
Type of method:
Laser scattering/diffraction
Type of particle tested:
primary particle
Type of distribution:
volumetric distribution
Percentile:
D50
Mean:
>= 0.5 - <= 4 µm
Remarks on result:
other: volume median diameter(migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.)

See document attached under background material.

Conclusions:
The median particle size (x50) is determined by customers' requirements and is < 10 microns with a typical range from 0.5 to 4 microns.
Executive summary:

The particle size distribution was analysed using laser diffraction. The method is standardized [ISO 13320-1: 1999 Particle size analysis - Laser diffraction methods - Part 1: General principles].

The median particle size (x50) is determined by customers' requirements and is < 10 microns with a typical range from 0.5 to 4 microns.

Description of key information

The median particle size (x50) is determined by customers' requirements and is < 10 microns with a typical range from 0.5 to 4 microns.

Additional information

The particle size distribution was analysed using laser diffraction. The method is standardized [ISO 13320-1: 1999 Particle size analysis - Laser diffraction methods - Part 1: General principles].

The median particle size (x50) is determined by customers' requirements and is < 10 microns with a typical range from 0.5 to 4 microns.