Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO No., other: United Nations (UN), UN no. ST/SG/AC.10/11/Rev.5: Recommendations on the Transport of Dangerous Goods, Part III
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO No., other: ASTM International, ASTM D 93: “Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester”, December 10, 2002.
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Key result
Flash point:
114 °C
Atm. press.:
1 019 hPa

Preliminary test:

The estimated flash-point of the test substance was 110°C.

Main test:

Test 1: 115 ºC

Test 2: 114 ºC

Interpretation of results:
GHS criteria not met
Conclusions:
The flash-point of the test substance was 114°C at 1019 hPa.
Executive summary:

The Pensky-Martens closed cup method was applied for the determination of the flash-point of OS2600. The test method was performed according to EU Method A.9, ISO 2719:2002 and ASTMD93. The flash-point of the test substance was 114°C at 1019 hPa.

Description of key information

The flash point of OS 2600 was 114 ºC at 1019 hPa.

The flash-point of MPKO, the hydrolysis product of OS2600, was determined to be 69 ºC at 102.1 hPa.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
114 °C

Additional information

Key study: A flash point test was performed in accordance with EU Method A.9 using a model APM-7 Pensky-Martens closed cup automatic flash point tester. The flash point of the substance was determined to be 114 ºC at 1019 hPa.

Supporting study: The Pensky-Martens closed cup method was applied for the determination of the flash-point of MPKO in accordance with EU Method A.9. The flash-point of the test substance was determined to be 69°C at 102.1 kPa.