Registration Dossier

Diss Factsheets

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

(from analogue) AIT expected = or >265°C

Key value for chemical safety assessment

Additional information

No data is available on the substance itself. However, a reliable experimental study, conducted according to a recognized EC/DIN method and under GLP, is available on an analogue.

Based on chemical similarity (both are alkene/ketone substituted trimethylcyclohexenes), and compared flash points, no significant difference is anticipated with the present dossier substance, so the read-across is considered justified for a key study. However, as the result is expressed as a limit value (analogue considered as a worst-case), it will not be retained as key value (no >= sign allowed).

This parameter is not relevant for classification, however the information is useful regarding process safety and potential additional fire hazard.

No particular hazard is anticipated in normal conditions of storage.