Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
09 February 2010 – 19 April 2010
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: This study has been performed according to OECD and EC guidelines and according to GLP principles

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Report date:
2010

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO No., other: United Nations (UN), UN no. ST/SG/AC.10/11/Rev.4: Recommendations on the Transport of Dangerous Goods, Part III: Classification Procedures, Test Methods and Criteria Relating to Explosives of Class 3, Class 4, Division 5.1 and Class 9, 2003.
Deviations:
no
Remarks:
this is not a ISO guideline, but UN guideline
Qualifier:
according to guideline
Guideline:
ISO No., other: ASTM International, ASTM D 93: “Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester”, December 10, 2002.
Deviations:
no
Remarks:
this is not a ISO guideline but a ASTM guidline
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup

Test material

Constituent 1
Reference substance name:
Rape oil, oxidized
EC Number:
305-871-3
EC Name:
Rape oil, oxidized
Cas Number:
95193-59-2
IUPAC Name:
95193-59-2
Details on test material:
- Name of test material (as cited in study report): Blown rapeseed oil
- Substance type: Yellow to brown viscous liquid
- Physical state: liquid
- Analytical purity: treated as 100% pure
- Expiration date of the lot/batch: 16 December 2010
- Stability under test conditions: stable
- Storage condition of test material: At room temperature in the dark

Results and discussion

Flash point
Flash point:
188 °C
Atm. press.:
1 019.3 hPa

Applicant's summary and conclusion

Conclusions:
The Pensky-Martens closed cup method was applied for the determination of the flash-point of Blown rapeseed oil. The flash-point of the test substance was 188°C.