Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
13 October 2010
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study conducted in compliance with recognised study guidelines and in compliance with GLP.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report date:
2010

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Details on test material:
Name: Reactive Blue F08-0170

Results and discussion

Pyrophoric solids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record. | Remarks: | Additional remarks: In the preliminary test the test item could not be ignited. Based on the results of the preliminary test, no main test was performed.
Pyrophoric liquids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record. | Remarks: | Additional remarks: In the preliminary test the test item could not be ignited. Based on the results of the preliminary test, no main test was performed.

Any other information on results incl. tables

In the preliminary test the test item could not be ignited. Based on the results of the preliminary test, no main test was performed.

Applicant's summary and conclusion

Interpretation of results:
non flammable
Remarks:
Migrated information
Conclusions:
The Reactive Blue F08-0170 could not be ignited. Therefore, the substance is considered not to be highly flammable.
Executive summary:

Two parallel flammability tests were performed. The tests were negative. The test item is not flammable in the conditions of this test.