Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
June-November 2011
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: study conducted according to the respective OECD guideline and under GLP

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2011
Report date:
2011

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
yes

Test material

Constituent 1
Chemical structure
Reference substance name:
Nadide
EC Number:
200-184-4
EC Name:
Nadide
Cas Number:
53-84-9
Molecular formula:
C21H27N7O14P2
IUPAC Name:
nadide
Details on test material:
- Substance type: organic
- Physical state: off-white powder
- Storage condition of test material: in refrigerator (2-8°C)

Results and discussion

Flammable solids
Test procedure:
burning time (test type not further specified)
Remarks:
or specified in description of method (migrated information)
Burning time:
> 240 s
Pyrophoric solids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.
Pyrophoric liquids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.

Applicant's summary and conclusion

Interpretation of results:
non flammable
Remarks:
Migrated information
Conclusions:
based on the results obtained, the test substance is considered „not highly flammable‟.
Executive summary:

A preliminary screening test was performed for the determination of the flammability of the test substance acc. to EC guideline A.10

No propagation of combustion of the test substance along 200 mm length of the pile within 4 minutes was observed. According to the guidelines, performance of the burning rate test is not required. Based on the results obtained, the test substance is considered „not highly flammable‟.