Registration Dossier

Physical & Chemical properties

Boiling point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Start date of the experimental work: 17/06/2009 and Completion date of the experimental work: 13/07/2009
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to
Guideline:
EU Method A.2 (Boiling Temperature)
Deviations:
no
GLP compliance:
yes
Type of method:
method according to Siwoloboff
Key result
Decomposition:
yes
Remarks:
starting decomposition at 167°C
Decomp. temp.:
167 °C
Remarks on result:
not determinable

Full test results:

 Run number
 Mass of sample used (g)  0.16 0.15 
 Boiling point temperature (°C)  N/A  N/A
 Corrected boiling Temperature (°C)  N/A  N/A

Result : Not determined

Test terminated at 167°C due to the sample starting to decompose

Conclusions:
Test results for the test item: No boiling point was determined due to the decomposition of the test item.
Test terminated at 167°C due to the sample starting to decompose.
Executive summary:

The test standard is conducted according to EC 440/2008 incorporating EC’s “Classification, Packaging & Labelling of Dangerous Substances in the European Union” Part 2, Testing methods, Jan ’97. Directive 92/69, Annex V to Council Directive 67/548/EC.

Description of key information

No boiling point could be determined.

The test terminated at 167°C due to the sample starting to decompose.

Key value for chemical safety assessment

Additional information