Registration Dossier

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Start date of the experimental work: 17/06/2009 and Completion date of the experimental work: 13/07/2009
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Conducted at a GLP accredited laboratory
Qualifier:
according to
Guideline:
other: laboratory test
Deviations:
no
GLP compliance:
yes
Type of method:
capillary viscometer (static)
Standard covering the apparatus used:
Measurment range: 1.2 to 60000 cSt
Accuracy: 0.6% to 1.2%
Testing Standard: CIPAC method MT 22 1994, reprinted 2007
Apparatus: Viscometer, Thermometer and Stop watch.
Key result
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
370
Remarks on result:
other: mean of 2 results

Full test results:

Run  Size No.  Time (sec)  Viscosity (cSt) 
37  10  370 
37  10  370 

Key C = Viscosity constant

Size No. = size of viscometer

Result : Kinetic Viscosity = 370 cSt @ 20°C

Conclusions:
Test Results for the test item: Kinetic Viscosity = 370 cSt @ 20°C (mean)

Description of key information

Kinetic Viscosity = 370 cSt @ 20°C

Key value for chemical safety assessment

Viscosity:
370 mm²/s (static)
at the temperature of:
20 °C

Additional information