Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Toxicological information

Genetic toxicity: in vitro

Currently viewing:

Administrative data

Endpoint:
in vitro gene mutation study in mammalian cells
Remarks:
Type of genotoxicity: gene mutation
Type of information:
calculation (if not (Q)SAR)
Remarks:
Migrated phrase: estimated by calculation
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)

Data source

Reference
Reference Type:
other: Authoritative data base
Title:
Danish QSAR study for CAS No.: 41687-30-3
Author:
Danish EPA Model
Year:
2012
Bibliographic source:
QSAR predictions by Danish Environmental Protection Agency (EPA)model powered by OASIS database:-Grant et al.

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: modelling database
Principles of method if other than guideline:
Data is from Multicase model.
GLP compliance:
no
Type of assay:
mammalian cell gene mutation assay

Test material

Constituent 1
Chemical structure
Reference substance name:
2-[(3-nitrophenyl)sulphonyl]ethanol
EC Number:
255-501-9
EC Name:
2-[(3-nitrophenyl)sulphonyl]ethanol
Cas Number:
41687-30-3
Molecular formula:
C8H9NO5S
IUPAC Name:
3 Nitrophenyl-B-Hydroxyethylsulfone
Details on test material:
- Name of test material (as cited in study report): 2-[(3-nitrophenyl)sulphonyl]ethanol
- Substance type: Organic
- Physical state: Solid

Method

Species / strain
Species / strain / cell type:
lymphocytes: mouse lymphoma (GTX)
Additional strain / cell type characteristics:
not specified
Metabolic activation:
not specified

Results and discussion

Test results
Species / strain:
lymphocytes: mouse lymphoma (GTX)
Metabolic activation:
not specified
Genotoxicity:
negative
Cytotoxicity / choice of top concentrations:
not specified
Vehicle controls validity:
not specified
Untreated negative controls validity:
not specified
Positive controls validity:
not specified
Remarks on result:
other: all strains/cell types tested
Remarks:
Migrated from field 'Test system'.

Applicant's summary and conclusion

Conclusions:
Interpretation of results (migrated information):
negative

Mutations in mouse lymphoma (GTX) with 2-[(3-nitrophenyl)sulphonyl]ethanol resulted as Negative
Executive summary:

Mutations in mouse lymphoma (GTX) with 2-[(3-nitrophenyl)sulphonyl]ethanol resulted as Negative