Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2011-03-16 to 2011-05-04
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Guideline study. GLP.
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Version / remarks:
(30 May 2008)
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Version / remarks:
(23 March 2006)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
effusion method: vapour pressure balance
Temp.:
20 °C
Vapour pressure:
0 hPa
Conclusions:
The vapour pressure of MDIPA Esterquat C18 unsatd. was determined to be 5E-06 hPa at 20°C.
Executive summary:

The vapour pressure of MDIPA Esterquat C18 unsatd. was determined according to OECD Guideline 104 (23 March 2006) and EU Method A.4 (30 May 2008) using the vapour pressure balance method. Based on the experimental results, the vapour pressure of the test item at 20°C was calculated to be 5E-06 hPa using the Antoine equation.

Description of key information

The vapour pressure of MDIPA Esterquat C18 unsatd. is reported to be 5E-06 hPa at 20°C (OECD Guideline 104/EU Method A.4; vapour pressure balance method).

Key value for chemical safety assessment

Vapour pressure:
0 hPa
at the temperature of:
20 °C

Additional information

The vapour pressure of MDIPA Esterquat C18 unsatd. was determined according to OECD Guideline 104 (23 March 2006) and EU Method A.4 (30 May 2008) using the vapour pressure balance method. Based on the experimental results, the vapour pressure of the test item at 20°C was calculated to be 5E-06 hPa using the Antoine equation.