Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
16 September - 15 December 2004
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Guideline study according to GLP

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2004
Report date:
2004

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Reference substance name:
Reaction mass of 5,12-dihydro-2,9-dimethylquino[2,3-b]acridine-7,14-dione and 5,12-dihydro-2-methylquino[2,3-b]acridine-7,14-dione and 5,12-dihydroquino[2,3-b]acridine-7,14-dione
EC Number:
909-082-0
Cas Number:
938065-79-3
Molecular formula:
Unspecified
IUPAC Name:
Reaction mass of 5,12-dihydro-2,9-dimethylquino[2,3-b]acridine-7,14-dione and 5,12-dihydro-2-methylquino[2,3-b]acridine-7,14-dione and 5,12-dihydroquino[2,3-b]acridine-7,14-dione

Results and discussion

Pyrophoric solids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.
Pyrophoric liquids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.

Any other information on results incl. tables

The test item could not be ignited with a flame during the preliminary test (contact time of about 2 minutes). In contact with the ignition source, the test item carbonized on the surface but could not be ignited with a flame. Based on these results, no main test with determination of the burning time was performed.

Applicant's summary and conclusion

Interpretation of results:
non flammable
Remarks:
Migrated information
Conclusions:
The test item could not be ignited with a flame during the preliminary test. Based on these results, no main test with determination of the burning time was performed and the substance is not considered a flammable solid.
Executive summary:

The test item could not be ignited with a flame in a guideline study and the criteria for classification as a flammable solid according to DIRECTIVE 67/548/EEC or REGULATION (EC) No 1272/2008 are not met.