Registration Dossier

Administrative data

Endpoint:
surface tension
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report Date:
2010

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.5 (Surface Tension)
GLP compliance:
yes
Type of method:
ring method

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Surface tension
Surface tension:
73 mN/m
Temp.:
20 °C
Conc.:
90 other: aqueous solution at 90 % of saturation

Applicant's summary and conclusion

Conclusions:
Non-surface active according to interpretation of results method A.5 (point 3.2).