Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Explosiveness

Currently viewing:

Administrative data

Endpoint:
explosiveness
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Read across to similar titanium complex that degrades to amines and glycols. Demonstrates that testing is impractical and will relate to degradation products.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1989
Report date:
1989

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.14 (Explosive properties)
Deviations:
no
GLP compliance:
yes

Test material

Constituent 1
Reference substance name:
107283-14-8
IUPAC Name:
107283-14-8

Results and discussion

Small-scale preliminary testsopen allclose all
Parameter:
other: More sensitive to shock than m-dinitrobenzene
Remarks:
migrated information
Remarks on result:
negative (not further specified)
Parameter:
other: More sensitive to friction than m-dinitrobenzene
Remarks:
migrated information
Remarks on result:
negative (not further specified)
Parameter:
other: Explosive under influence of flame
Remarks:
migrated information
Remarks on result:
negative (not further specified)

Applicant's summary and conclusion

Interpretation of results:
non explosive
Remarks:
Migrated information
Conclusions:
It was reported that there is no explosive property of TILCOM AT34 induced by flame, by shock or by friction
Therefore it can be concluded that Vertec AT34 (Tilcon AT34) is non explosive and therefore not classified