Registration Dossier

Administrative data

First-aid measures

Description of first aid measures
Immediately remove contaminated clothing. If danger of loss of consciousness, place patient in recovery position and transport accordingly. Apply artificial respiration if necessary. First aid personnel should pay attention to their own safety.

If inhaled:
Keep patient calm, remove to fresh air, seek medical attention.

On skin contact:
Wash thoroughly with soap and water.

On contact with eyes:
Immediately wash affected eyes for at least 15 minutes under running water with eyelids held open, consult an eye specialist.

On ingestion:
Rinse mouth immediately and then drink plenty of water, seek medical attention.

Indication of any immediate medical attention and special treatment needed
Treatment: Treat according to symptoms (decontamination, vital functions), no known specific antidote. Pulmonary odema prophylaxis. Medical monitoring for at least 24 hours.

Fire-fighting measures

Extinguishing media
Suitable extinguishing media:
dry powder, foam, carbon dioxide

Special hazards arising from the substance or mixture
nitrogen oxides, carbon oxides
The substances/groups of substances mentioned can be released in case of fire. Under certain conditions in case of fire other hazardous combustion products may be generated.

Advice for fire-fighters
Special protective equipment:
Wear self-contained breathing apparatus and chemical-protective clothing.

Further information:
Collect contaminated extinguishing water separately, do not allow to reach sewage or effluent systems.

Accidental release measures

Personal precautions, protective equipment and emergency procedures
Avoid inhalation. Avoid contact with the skin, eyes and clothing.

Environmental precautions
Do not empty into drains.

Methods and material for containment and cleaning up
For small amounts: Pick up with suitable appliance and dispose of.
For large amounts: Pick up with suitable appliance and dispose of.

Handling and storage

Precautions for safe handling
Ensure thorough ventilation of stores and work areas.

Protection against fire and explosion:
Take precautionary measures against static discharges.

Prevent electrostatic charge - sources of ignition should be kept well clear - fire extinguishers should be kept handy.

Conditions for safe storage, including any incompatibilities
Segregate from acids and acid forming substances.

Suitable materials for containers: carbon steel (iron)
Further information on storage conditions: Containers should be stored tightly sealed in a dry place. Keep container dry because product takes up the humidity of air.

Storage stability:
Storage temperature: 25 °C
Storage duration: 24 Months
From the data on storage duration in this safety data sheet no agreed statement regarding the warrantee of application properties can be deduced.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (IMDG)

Remarksopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Control parameters

Components with occupational exposure limits

No occupational exposure limits known.

Exposure controls
Personal protective equipment
Respiratory protection:
Breathing protection if gases/vapours are formed. Gas filter for gases/vapours of organic compounds (boiling point >65 °C, e. g. EN 14387 Type A)

Hand protection:
Suitable materials also with prolonged, direct contact (Recommended: Protective index 6, corresponding > 480 minutes of permeation time according to EN 374):
butyl rubber (butyl) - 0.7 mm coating thickness
fluoroelastomer (FKM) - 0.7 mm coating thickness
Suitable materials short-term contact and/or splashes (recommended: At least protective index 2, corresponding > 30 minutes of permeation time according to EN 374)
chloroprene rubber (CR) - 0.5 mm coating thickness
nitrile rubber (NBR) - 0.4 mm coating thickness
Supplementary note: The specifications are based on tests, literature data and information of glove manufacturers or are derived from similar substances by analogy. Due to many conditions (e.g. temperature) it must be considered, that the practical usage of a chemical-protective glove in practice may be much shorter than the permeation time determined through testing.
Manufacturer's directions for use should be observed because of great diversity of types.

Eye protection:
Tightly fitting safety goggles (cage goggles) (e.g. EN 166) and face shield.

General safety and hygiene measures
Handle in accordance with good industrial hygiene and safety practice. Wearing of closed work clothing is required additionally to the stated personal protection equipment. Avoid inhalation of vapour. Avoid contact with the skin, eyes and clothing.

Stability and reactivity

Reactivity
No hazardous reactions if stored and handled as prescribed/indicated.


Corrosion to metals:
Corrosive effects to metal are not anticipated.

Chemical stability
The product is stable if stored and handled as prescribed/indicated.

Possibility of hazardous reactions
Evolution of heat under influence of acids. Violent reaction with phosphorus pentoxide. May react with oxidizing agents. Reacts with aldehydes. Reacts with diisocyanates. Reacts with carbon dioxide. Reacts with concentrated sulfuric acid. Reacts with strong acids. Incompatible with acid chlorides and acid anhydrides.


Conditions to avoid
Avoid contact with air.

Incompatible materials

Substances to avoid:
chloroformates, chlorinating agents, epoxide, isocyanates, reactive carbonyl compounds, strong oxidizing agents, strong acids, acid chlorides, acid anhydrides

Disposal considerations

Waste treatment methods

Incinerate in suitable incineration plant, observing local authority regulations.
A waste code in accordance with the European waste catalog (EWC) cannot be specified, due to dependence on the usage.
The waste code in accordance with the European waste catalog (EWC) must be specified in cooperation with disposal agency/manufacturer/authorities.


Contaminated packaging:
Contaminated packaging should be emptied as far as possible; then it can be passed on for recycling after being thoroughly cleaned.