Registration Dossier

Administrative data

Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2009
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: guidance followed, no GLP

Data source

Referenceopen allclose all

Reference Type:
study report
Title:
Unnamed
Year:
2009
Report Date:
2009
Reference Type:
study report
Title:
Unnamed
Year:
2009
Report Date:
2009

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
Deviations:
no
GLP compliance:
no
Type of method:
capillary viscometer (static)

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Viscosityopen allclose all
Temp.:
other: 80.0°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
ca. 1.75
Temp.:
other: 100.0°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
ca. 1.5
Remarks on result:
other: high purity acenaphthene

Any other information on results incl. tables

acenaphthene:

No.

Viscosity

Unit

1

1.80

mm2.s-1

2

1.70

mm2.s-1

 

Standard deviation: 0.07 mm2.s-1

Average kinematic viscosity: 1.75 ± 0.07 mm2.s-1at 80 °C

high purity acenaphthene:

No.

Viscosity

Unit

1

1.50

mm2.s-1

2

1.50

mm2.s-1

 Standard deviation: 0.00 mm2.s-1

 Average kinematic viscosity: 1.50 mm2.s-1at 100 °C

Applicant's summary and conclusion