Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Environmental fate & pathways

Biodegradation in water: screening tests

Currently viewing:

Administrative data

Endpoint:
biodegradation in water: ready biodegradability
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Guideline study. Basic data given, accpetable for assessment

Data source

Reference
Reference Type:
publication
Title:
Biodegradation and Bioconcentration of Existing Chemical Substances under the Chemical Substances Control Law
Author:
MITI
Year:
2002
Bibliographic source:
http://www.safe.nite.go.jp
Report date:
2002

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 301 C (Ready Biodegradability: Modified MITI Test (I))
GLP compliance:
not specified

Test material

Constituent 1
Chemical structure
Reference substance name:
4-isopropylaniline
EC Number:
202-797-2
EC Name:
4-isopropylaniline
Cas Number:
99-88-7
Molecular formula:
C9H13N
IUPAC Name:
4-(propan-2-yl)aniline

Study design

Oxygen conditions:
aerobic
Inoculum or test system:
mixture of sewage, soil and natural water
Details on inoculum:
Source of inoculum/activated sludge (e.g. location, sampling depth, contamination history, procedure): In March, June, September, and December, sludge was sampled at the following 10 places in Japan: 1. Fukogawa city sewage plant, 2. Fukashiba industry sewage plant, 3. Nakahama city sewage plant, 4. Ochiai city sewage plant, 5. Kitakami river, 6. Shinano river, 7. Yoshino river, 8. Lake Biwa, 9. Hiroshima bay, 10. Dookai bay; sampling: 1. City sewage: Returned sludge from sewage plants was taken. 2. Rivers, lake and sea: Surface water and surface soil which were in contact with atmosphere were collected

- Method of cultivation: About 30 minutes after ceasing aeration to the sludge mixture, supernatant corresponding to about 1/3 of the whole volume was removed. Then the equal volume of dechlorinated water was added to the remaining portion and aerated again, followed by addition of synthetic sewage at a concentration of 0.1% (w/v). This procedure was repeated once every day. The culturing was carried out at 25 ± 2 °C. 5 L of the filtrate of the supernatant of old activated sludge was mixed with 500 mL of the filtrate of the supernatant of new sludge and cultured at pH 7.0 ± 1.0 under sufficient aeration using prefiltered open air. During the cultivation, appearance of the supernatant, precipitability, formation of flock, pH, dissolved oxygen concentration in the solution and temperature were checked and necessary adjustments were made, Microflora in the activated sludge was microscopically observed and sludge with no abnormal symptom was used for the test.
- Concentration of sludge: 30 mg/L
Duration of test (contact time):
28 d
Initial test substance concentration
Initial conc.:
100 mg/L
Based on:
test mat.
Parameter followed for biodegradation estimationopen allclose all
Parameter followed for biodegradation estimation:
O2 consumption
Parameter followed for biodegradation estimation:
TOC removal
Details on study design:
TEST CONDITIONS
- Composition of medium: 3 mL each of four stock solutions, as described in JIS K 0102-1986-21, are diluted to 1000 mL with purified water
- pH: 7.0
- pH adjusted: yes
- Suspended solids concentration: determined according to Method Japanese Industrial standards (JIS) K 0102-1986-14.1
TEST SYSTEM
- Culturing apparatus: Closed system oxygen consumption measuring apparatus (Coulometer: Ohkura Electric Co., Ltd.); 300 mL vessel, absorbent for evolving carbon dioxide Soda lime No .l (extra pure reagent, Wako Pure Chemical Industries, Ltd.).
- Number of culture flasks/concentration: 1
- Measuring equipment: Coulometer, Okhura Electric Co., Ltd.
- Test performed in open system: no
- Details of trap for CO2 and volatile organics if used: soda lime, extra pure, Wako Pure Chemical Industries, Ltd.)
CONTROL AND BLANK SYSTEM
- Inoculum blank: yes
- Abiotic sterile control: yes
- Toxicity control: no

Results and discussion

% Degradationopen allclose all
Parameter:
% degradation (TOC removal)
Value:
0
Sampling time:
28 d
Parameter:
% degradation (O2 consumption)
Value:
1
Sampling time:
28 d
Parameter:
other: HPLC
Value:
2
Sampling time:
28 d

Applicant's summary and conclusion

Interpretation of results:
under test conditions no biodegradation observed
Executive summary:

One guideline study investigating the ready biodegradability of the substance is available. The biodegradation of the substance was tested in a modified MITI test according to OECD guideline 301C. At test termination after 28 days the test substance was degraded by 0 -2 % (MOE, 1998). Thus, the test substance is not readily biodegradable according to OECD criteria.