Diss Factsheets

Physical & Chemical properties

Water solubility

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
water solubility
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2021-06-18
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.6 (Water Solubility)
Version / remarks:
2014
Deviations:
yes
Remarks:
A water solubility test following the OECD 105 and EC A.6. guidelines was technically not feasible because no saturated solution could be prepared due to the very high water solubility of the test item.
Qualifier:
according to guideline
Guideline:
OECD Guideline 105 (Water Solubility)
Version / remarks:
1995
Deviations:
yes
Remarks:
A water solubility test following the OECD 105 and EC A.6. guidelines was technically not feasible because no saturated solution could be prepared due to the very high water solubility of the test item.
GLP compliance:
yes (incl. QA statement)
Type of method:
other: miscibility test
Key result
pH:
>= 2.23 - <= 3.59
Remarks on result:
completely miscible

In conclusion, Methyl vinyl glycolate (MVG) is miscible in water. For the details see Table 1.


 


Table 1 Water solubility test
















































Test Item / g



Water / g



Observation



pH value



1.13



9.11



clear, homogeneous, single-phase liquid



3.59



1.12



9.06



clear, homogeneous, single-phase liquid



3.57



1.10



1.00



clear, homogeneous, single-phase liquid



2.97



1.10



1.00



clear, homogeneous, single-phase liquid



2.99



4.91



0.50



clear, homogeneous, single-phase liquid



2.24



4.91



0.50



clear, homogeneous, single-phase liquid



2.23


Conclusions:
The test item is completely miscible with water.
Executive summary:

An experimental study was conducted according to OECD Test guideline 105 and Regulation (EC) No 440/2008 Method A.6. The water solubility test following the guidelines was technically not feasible because no saturated solution could be prepared due to the very high water solubility of the test item. In conclusion the test item is completely miscible in water.

Description of key information

The test item is completely miscible with water. For risk assessment purposes the upper limit of EUSES = 100000 mg/L will be used.

Key value for chemical safety assessment

Water solubility:
100 000 mg/L
at the temperature of:
20 °C

Additional information

An experimental study was conducted according to OECD Test guideline 105 and Regulation (EC) No 440/2008 Method A.6. The water solubility test following the guidelines was technically not feasible because no saturated solution could be prepared due to the very high water solubility of the test item. The test item was mixed with water in the ratios 1:9, 1:1 and 9:1 and the pH was determined. In conclusion the test item is completely miscible in water.