Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: - | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Eye irritation
Administrative data
- Endpoint:
- eye irritation: in vitro / ex vivo
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- April 28 - June 09, 2016
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
Data source
Reference
- Reference Type:
- study report
- Title:
- Unnamed
- Year:
- 2 016
- Report date:
- 2016
Materials and methods
Test guideline
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 438 (Isolated Chicken Eye Test Method for Identifying i) Chemicals Inducing Serious Eye Damage and ii) Chemicals Not Requiring Classification for Eye Irritation or Serious Eye Damage)
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
Test material
- Test material form:
- solid: particulate/powder
- Details on test material:
- Batch No.: 2016JAN-15kg
Expiry Date: 01 January 2020
Appearance: Blue-white powder
Storage: Room temperature (15-25°C)
Safety precautions: Routine safety precautions (lab coat, gloves, safety glasses, face mask) for unknown materials were applied to assure personnel health and safety.
Constituent 1
impurity 1
- Specific details on test material used for the study:
- Batch No.: 2016 JAN-15kg
Expiry Date: 01 January 2020
Appearance: Blue-white powder
Storage: Room temperature (15-25°C)
Test animals / tissue source
- Species:
- chicken
- Details on test animals or tissues and environmental conditions:
- Head collection was performed by a slaughter house technician. Heads were removed immediately after sedation of the chickens (sedation was happened by electric current). The heads were transported to Toxi-Coop ZRT at the earliest convenience for use approximately within 2 hours from collection. The ambient temperature was optimal (19.0ºC to 19.4ºC) during the transport. All eyes used in the assay were from the same groups of eyes collected on one specific day. After collection, the heads were inspected for appropriate quality and wrapped with paper moistened with saline, then placed in a plastic box that can be closed (4 5 heads/box). After removing the head from the plastic box, it was put on soft paper. The eyelids were carefully cut away with scissors, avoiding damaging the cornea. One small drop of fluorescein solution 2 (w/v) % was applied onto the cornea surface for a few seconds and subsequently rinsed off with 20 mL isotonic saline Then the fluorescein-treated cornea was examined with hand-held slit lamp or slit lamp microscope, with the eye in the head, to ensure that the cornea was not damaged. If the cornea was in good condition, the eyeball was carefully removed from the orbit. The eyeball was carefully removed from the orbit by holding the nictitating membrane with a surgical forceps, while cutting the eye muscles with bent scissors without cutting off the optical nerve too short. The procedure avoided pressure on the eye in order to prevent distortion of the cornea and subsequent corneal opacity. Once removed from the orbit, the eye was placed onto damp paper and the nictitating membrane was cut away with other connective tissue. The prepared eyes were kept on the wet papers in a closed box so that the appropriate humidity was maintained.
Test system
- Vehicle:
- unchanged (no vehicle)
- Controls:
- yes, concurrent positive control
- yes, concurrent negative control
- Amount / concentration applied:
- The test item was applied in its original form, no formulation was required. The test item was finely ground before application.
- Duration of treatment / exposure:
- Start and end of experimental phase: May 06, 2016
- Details on study design:
- Isolated Chicken Eye Test (ICET)
REMOVAL OF TEST SUBSTANCE: The time of application was monitored, then after an exposure period of 10 seconds from the end of the application the cornea surface was rinsed thoroughly with 20 mL saline solution at ambient temperature, while taking care not to damage the cornea but attempting to remove all the residual test item if possible. The eye in the holder was then returned to its chamber. The time while the eye was out of the chamber was limited to the minimum.
The Imidazole and test item were stuck on the corneas’ surface in all eyes at 30 minutes after the post-treatment rinse. The gentle rinsing with 20 mL saline was performed in all Imidazole and test item treated eyes after the 30, 75, 120 and 180 minutes of observation. The cornea surfaces were not totally cleared at 240 minutes after the post-treatment rinse.
Results from corneal opacity, swelling, and fluorescein retention were evaluated separately to generate an ICE (Isolated Chicken Eye) class for each endpoint. The ICE classes for each endpoint were then combined to generate an Irritancy Classification for each test substance.
TOOL USED TO ASSESS SCORE: hand-slit lamp / biomicroscope / fluorescein:
The appropriate number of eyes was selected and after being placed in the superfusion apparatus, the selected eyes were examined again with the slit lamp microscope to ensure that they were in good condition. Eyes with a high baseline fluorescein staining (i.e., > 0.5) or corneal opacity score (i.e., > 0.5) were rejected. The cornea thickness was measured using the depth measuring device on the slit lamp microscope (Haag-Streit BQ 900) with the slit-width set at 9½, equalling 0.095 mm.
Results and discussion
In vitro
Results
- Irritation parameter:
- in vitro irritation score
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Remarks on result:
- no indication of irritation
- Other effects / acceptance of results:
- There was no visible damage on test system.
Range of historical values if different from the ones specified in the test guideline: Positive and negative controls showed the expected results. The experiment was considered to be valid.
Applicant's summary and conclusion
- Interpretation of results:
- GHS criteria not met
- Conclusions:
- In this in vitro eye corrosive and severe irritant study, using the Isolated Chicken Eye model with Neodymium fluoride oxide, magnesium doped, no ocular corrosion or severe irritation potential was observed. The overall ICE score was 1xI, 1xII, 1xIII.
According to the guideline OECD 438, Neodymium fluoride oxide, magnesium doped overall in vitro classification is neither UN GHS Classification Category I (an ocular corrosive or severe eye irritant) nor No Category. Thus, according to the guideline OECD 438, test item has been categorized as “No prediction can be made”. - Executive summary:
The purpose of this Isolated Chicken Eye Test (ICET) was to evaluate the potential ocular corrosivity and irritancy of the test item Neodymium fluoride oxide, magnesium doped by its ability to induce toxicity in enucleated chicken eyes. The test compound was applied in a single dose (30 mg/eye) onto the cornea of isolated chicken eyes in order to potentially classify the test compound as either 1: causing "serious eye damage" (category 1 of the Globally Harmonised System for the Classification and Labelling of Chemicals (GHS)), or 2: not requiring classification for eye irritation or serious eye damage according to the GHS. Tested corneas were evaluated pre-treatment and at approximately 30, 75, 120, 180, and 240 minutes after the post-treatment rinse. The endpoints evaluated were corneal opacity, swelling, fluorescein retention, and morphological effects. All of the endpoints, with the exception of fluorescein retention (which was determined only at pre-treatment and 30 minutes after test substance exposure) were determined at each of the above time points.
The Neodymium fluoride oxide, magnesium doped and Imidazole (positive control) were ground before use in the study. They were applied in an amount of 0.03 g/eye by powdering the entire surface of the cornea attempting to cover the cornea surface uniformly with the test substance or positive control. Three test item treated eyes and three positive control eyes were used in this study.
One negative control eye was treated with 30 µL saline solution. After an exposure period of 10 seconds from the end of the application the cornea surface was rinsed thoroughly with ~20 mL saline solution at ambient temperature and this procedure was repeated for each eye. In this ICET, Neodymium fluoride oxide, magnesium doped did not cause ocular corrosion or severe irritation in the enucleated chicken eyes.The overall ICE class was 1xI, 1xII, 1xIII. Positive and negative controls showed the expected results. The experiment was considered to be valid.
According to the guideline OECD 438, Neodymium fluoride oxide, magnesium doped overall in vitro classification is neither UN GHS Classification Category I (an ocular corrosive or severe eye irritant) nor No Category. Thus, according to the guideline OECD 438, test item has been categorized as “No prediction can be made”.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.
Although ECHA is providing a lot of online material in your language, part of this page is only in English. More about ECHA’s multilingual practice.
Welcome to the ECHA website. This site is not fully supported in Internet Explorer 7 (and earlier versions). Please upgrade your Internet Explorer to a newer version.
the-echa-website-uses-cookies
find-out-more-on how-we-use-cookies