Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2003
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods with acceptable restrictions
Remarks:
The study was conducted in accordance with recognised method, but not described in details, and non-GLP. The substance is considered to be adequately characterised. Therefore validation applies with restrictions.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2003
Report date:
2003

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: not specified
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Setaflash apparatus

Test material

Constituent 1
Chemical structure
Reference substance name:
methyl (3E)-4-methyl-6-(2,6,6-trimethylcyclohex-1-en-1-yl)hex-3-enoate
EC Number:
607-380-2
Cas Number:
244626-75-3
Molecular formula:
C17H28O2
IUPAC Name:
methyl (3E)-4-methyl-6-(2,6,6-trimethylcyclohex-1-en-1-yl)hex-3-enoate
Test material form:
liquid
Details on test material:
Appearance: light yellow liquid

Results and discussion

Flash point
Key result
Flash point:
164 °C
Atm. press.:
984 mBar

Any other information on results incl. tables

Accuracy: ± 2 °C

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The Flash Point of the test substance was measured using a Setaflash apparatus, closed cup method.
Flash point was measured as 164°C at 984 mbar.
Executive summary:

The Flash Point of the test substance was measured using a Setaflash apparatus, closed cup method.

Flash point was measured as 164°C at 984 mbar.