Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
explosiveness, other
Remarks:
See below for details
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2012
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Guideline study (EU A.14, UN-Tests 1(b)/2(b), 3(a)(ii), 3(b)(i), F.3, 1(c)(i)/C.1).

Data source

Referenceopen allclose all

Reference Type:
study report
Title:
Unnamed
Year:
2012
Report date:
2012
Reference Type:
study report
Title:
Unnamed
Year:
2012
Report date:
2012

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.14 (Explosive properties)
Qualifier:
according to guideline
Guideline:
other: UN Recommendations on the TRANSPORT OF Dangerous GOODS: Manual of Tests and Criteria, 5th edition, New York and Geneva, 2009: UN-Tests 1(b)/2(b), 3(a)(ii), 3(b)(i), F.3, 1(c)(i)/C.1.

Test material

Constituent 1
Chemical structure
Reference substance name:
2-[(4-chloro-2-nitrophenyl)azo]-N-(2-chlorophenyl)-3-oxobutyramide
EC Number:
229-355-1
EC Name:
2-[(4-chloro-2-nitrophenyl)azo]-N-(2-chlorophenyl)-3-oxobutyramide
Cas Number:
6486-23-3
Molecular formula:
C16H12Cl2N4O4
IUPAC Name:
2-[(4-chloro-2-nitrophenyl)diazenyl]-N-(2-chlorophenyl)-3-oxobutanamide
Test material form:
solid: nanoform, no surface treatment

Results and discussion

Small-scale preliminary tests
Key result
Parameter:
other: Explosive (not specified)
Remarks on result:
negative (not further specified)

Any other information on results incl. tables

Residual moisture:

The test item contains a residual moisture of 0.1 wt.-%, which was determined by drying the test item under vacuum.

Heating under confinement: Koenen-Test (UN-Test: 1(b)/2(b)

Tests with orifice plates with 1.0 and 2.0 mm diameter orifice were performed.

No.

Sample weight / g

Diameter orifice plate / mm

Reaction time t1 /s

Reaction time t2 /s

Reaction

Appearance of tube

1

15.64

1

22

>300

t1: Sparkling
t2: No reaction

0, Unchanged

2

15.39

1

26

>300

t1: Sparkling
t2: No reaction

0, Unchanged

3

15.37

1

24

>300

t1: Sparkling
t2: No reaction

0, Unchanged

4

15.36

2

18

>300

t1: Sparkling
t2: No reaction

0, Unchanged

5

15.44

2

20

>300

t1: Sparkling
t2: No reaction

0, Unchanged

6

15.33

2

17

>300

t1: Sparkling
t2: No reaction

0, Unchanged

t1: time to first reaction: e.g. burning
t2: time to main reaction: e.g. frizzling, bursting of tube

The test item shows no reaction with either an orifice plate with an orifice-diameter of 1 mm or 2 mm on heating under confinement.

Due to the chemical structure and the physical state (pure solid) an explosion for an orifice-diameter of 6 mm can be excluded.

Therefore, the Koenen-Test (UN-Test 1(b)/2(b)) of the test item shows no effect on heating under confinement with an orifice plate with an orifice diameter of 1 or 2 mm.

The assessment of the results with regard to test series 1 (b) was “-”.

The assessment of the results with regard to test series 2 (b) was “-”.

Mechanical sensitivity: Friction: BAM Friction Apparatus (UN-Test: 3(b)(i))

No explosion was observed within 6 tests using a 360 N loading.

The assessment of the results with regard to test series 3(b)(i) was “-”.

Mechanical sensitivity: Impact: BAM Fallhammer (UN-Test: 3(a)(ii))

No explosion was observed within 6 tests dropping the 10 kg mass from 0.50 m (50 J).

The assessment of the results with regard to test series 3(a)(ii) was “-”.

BAM Trautzl test (UN-Test F.3)

The assessment of the results was “No” (the expansion of the lead block was less than 10 cm³ per 10 g of sample).

Due to this result the result of the UN Gap Test 1(a)/2(a) is deemed to be “-”.

Time/Pressure Test (UN-Test 1(c)(i)/2(c)(i)/C.1)

The assessment of the results with regard to test series 1(c)(i) was “-” (gauge pressure of 2070 kPa was not reached: substance showed not the ability to deflagrate).

The assessment of the results with regard to test series 2(c)(i) was “-” (gauge pressure of 2070 kPa was not reached: substance showed no or slowly deflagration).

The assessment of the results with regard to test series C.1 was “No” (a pressure rise to 2070 kPa was not achieved).

Applicant's summary and conclusion

Interpretation of results:
non explosive
Conclusions:
UN-Transport regulations:
The test item does not have to be classified as explosive in Class 1 according to the UN-Transport Regulations.
GHS and EC 1272/2008 (CLP-Guideline), Annex 1: 2.1:
The test item does not have to be classified as explosive according to GHS and EC 1272/2008 (CLP-Guideline) Annex 1: 2.1..
EC 440/2008:
The test item has no explosive properties according to EC 440/2008, Part A, A.14.
Executive summary:

Due to the high decomposition energy (see section 4.2), it was tested whether the test item shows some effect on heating under confinement according to UN-Test series: 1(b)/2(b): Koenen-Test, is sensitive to impact according to UN-Test series: 3(a)(ii): BAM Fallhammer or is sensitive to friction according to UN-Test series: 3(b)(i): BAM friction apparatus (Class 1). Additionally, the BAM Trautzl-Test (UN-Test F.3) and the Time/Pressure-Test (UN-Test 1(c)(i)/C.1) were performed.

Heating under confinement: Koenen-Test (UN-Test: 1(b)/2(b)): The Koenen-Test (UN-Test 1(b)/2(b)) of the test item shows no effect on heating under confinement with an orifice plate with an orifice diameter of 1 or 2 mm. The assessment of the results with regard to test series 1 (b) was “-”. The assessment of the results with regard to test series 2 (b) was “-”.

Mechanical sensitivity: Friction: BAM Friction Apparatus (UN-Test: 3(b)(i)): The assessment of the results with regard to test series 3(b)(i) was “-”.

Mechanical sensitivity: Impact: BAM Fallhammer (UN-Test: 3(a)(ii)): The assessment of the results with regard to test series 3(a)(ii) was “-”.

BAM Trautzl test (UN-Test F.3): The assessment of the results was “No”. Due to this result the result of the UN Gap Test 1(a)/2(a) is deemed to be “-”.

Time/Pressure Test (UN-Test 1(c)(i)/2(c)(i)/C.1): The assessment of the results with regard to test series 1 (c) (i) was “-”. The assessment of the results with regard to test series 2 (c) (i) was “-”. The assessment of the results with regard to test series C.1 was “No”.

The test item has no explosive properties.