Physical & Chemical properties

Partition coefficient

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Study period:
30 March 2018 to 14 September 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
Version / remarks:
2004
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7570 (Partition Coefficient, n-octanol / H2O, Estimation by Liquid Chromatography)
Version / remarks:
1996
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: EC Guideline A.24. Partition Coefficient (n-octanol/water), High Performance Liquid Chromatography (HPLC) Method.
Version / remarks:
2016
Deviations:
no
GLP compliance:
yes
Type of method:
HPLC method
Partition coefficient type:
octanol-water
Analytical method:
liquid chromatography
Key result
Type:
log Pow
Partition coefficient:
> 7.2
Temp.:
35 °C
pH:
7
Key result
Type:
Pow
Partition coefficient:
> 16 000 000
Temp.:
35 °C
pH:
7
Details on results:
In the chromatogram of the test material solution, several peaks with a retention time between 23.3 and 36.8 minutes were observed. Under the same analytical conditions, the retention time of 4,4’-DDT (log Pow = 6.5) was 11.4 and the retention time of benzo[ghi]perylene (log Pow = 7.2) was 18.2 minutes.
It was concluded that the log Pow of test material was > 7.2 (Pow > 1.6 x 10^7).
Conclusions:
Under the conditions of this study the log Pow (and Pow) values of the test material at neutral pH were > 7.2 (Pow > 1.6 x 10^7).
Executive summary:

The partition coefficient of the test material was investigated in accordance with the standardised guidelines OECD 117, EU Method A.24 and OPPTS 830.7570, under GLP conditions using the HPLC method.

In the chromatogram of the test material solution, several peaks with a retention time between 23.3 and 36.8 minutes were observed. Under the same analytical conditions, the retention time of 4,4’-DDT (log Pow = 6.5) was 11.4 and the retention time of benzo[ghi]perylene (log Pow = 7.2) was 18.2 minutes. It was concluded that the log Pow of test material was > 7.2 (Pow > 1.6 x 10^7).

Under the conditions of this study the log Pow (and Pow) values of the test material at neutral pH were > 7.2 (Pow > 1.6 x 10^7).

Description of key information

Under the conditions of the study the log Pow (and Pow) values of the test material at neutral pH were > 7.2 (Pow > 1.6 x 10^7).

Key value for chemical safety assessment

Additional information

The partition coefficient of the test material was investigated in accordance with the standardised guidelines OECD 117, EU Method A.24 and OPPTS 830.7570, under GLP conditions using the HPLC method. The study was awarded a reliability score of 1 in accordance with the criteria set forth by Klimisch et al. (1997).

In the chromatogram of the test material solution, several peaks with a retention time between 23.3 and 36.8 minutes were observed. Under the same analytical conditions, the retention time of 4,4’-DDT (log Pow = 6.5) was 11.4 and the retention time of benzo[ghi]perylene (log Pow = 7.2) was 18.2 minutes. It was concluded that the log Pow of test material was > 7.2 (Pow > 1.6 x 10^7).

Under the conditions of this study the log Pow (and Pow) values of the test material at neutral pH were > 7.2 (Pow > 1.6 x 10^7).