Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Environmental fate & pathways

Adsorption / desorption

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
adsorption / desorption
Remarks:
other: adsorption/desorption screening test
Type of information:
read-across from supporting substance (structural analogue or surrogate)
Adequacy of study:
key study
Study period:
2003
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Justification for type of information:
Considering the structural similarities between iodo(triphenylphosphino)copper and iodotris(triphenylphosphino)copper and the almost identical physical and chemical properties, especially partition coefficients and water solubilites, it can be expected that the substances will show quite similar behaviour with respect to adsorption and desorption.
Reason / purpose for cross-reference:
read-across source
Qualifier:
according to guideline
Guideline:
other: OECD 121
GLP compliance:
yes
Type of method:
HPLC estimation method
Media:
soil
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: 219001
- Expiration date of the lot/batch: January 01, 2004


STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: dry, room temperature, closed container
Test temperature:
30 °C ± 1 °C
Details on study design: HPLC method:
EQUIPMENT
- Apparatus: Shimadzu HPLC
- Type: LC-6A isocratic pump, a Rheodyne seven port valve Model 7125, a column oven CT0-6A, an UV-VIS spectrophotometric detector SPD-6A V and a C-R4A Chromatopac Processor
- Type, material and dimension of analytical (guard) column: Ultrasep ES Cyano; 250 x 3 mm ID, 5 μm
- Detection system: 250 nm

MOBILE PHASES
- Type: A: organic phase ( acetonitrile), B: watery phase, A : B = 55 : 45 % (v/v)
- Solutes for dissolving test and reference substances: acetonitrile

DETERMINATION OF DEAD TIME
- Method: by means of homologous series / by inert substances which are not retained by the column

REFERENCE SUBSTANCES
- Identity: Thiourea, Linuron, 1,2,3-Trichlorbenzene,Pyrazophos, Phenanthrene, Hexachlorbenzene, e,e'-DDT

DETERMINATION OF RETENTION TIMES
- Quantity of test substance introduced in the column: 2
- Quantity of reference substances: 7

REPETITIONS
- Number of determinations: 2
Type:
Koc
Value:
5.9 dimensionless
Temp.:
30 °C
Validity criteria fulfilled:
yes
Conclusions:
Tue retention times of the test item were 3.649 min (first analysis) and 3.691 min (second
analysis). By use of the linear function of log k versus log Koc the adsorption coefficient of the test item was calculated. The mean value for log Koc by use of two single values is 5.9.
Executive summary:

The mean value for log Koc by use of two single values is 5.9.

Description of key information

Key value for chemical safety assessment

Koc at 20 °C:
800 000

Additional information

[LogKoc: 5.9]