Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Justification for type of information:
Experimental data obtained using standard method of analysis
Qualifier:
according to guideline
Guideline:
other: As mention below
Principles of method if other than guideline:
The particle size distribution of test chemical was determined by granulometric analysis with rotap sieve shaker.
GLP compliance:
no
Type of method:
sieving
Type of particle tested:
primary particle
Type of distribution:
counted distribution
Key result
Percentile:
D50
Remarks on result:
other: Mass median diameter
No.:
#1
Size:
150 µm
Distribution:
41.46 %
No.:
#2
Size:
106 µm
Distribution:
27.19 %
No.:
#3
Size:
75 µm
Distribution:
20.28 %
No.:
#4
Size:
53 µm
Distribution:
8.18 %
No.:
#5
Size:
25 µm
Distribution:
0.68 %
No.:
#6
Size:
10 µm
Distribution:
0.029 %
Conclusions:
The particle size distribution of test chemical was determined by granulometric analysis with rotap sieve shaker. The particle size distribution was found to be in the range of 150 microns to 10 microns.
Executive summary:

The particle size distribution of test chemical was determined by granulometric analysis with rotap sieve shaker. The particle size distribution was found to be in the range of 150 microns to 10 microns.

Description of key information

The particle size distribution of test chemical was determined by granulometric analysis with rotap sieve shaker. The particle size distribution was found to be in the range of 150 microns to 10 microns.

Additional information

The particle size distribution of test chemical was determined by granulometric analysis with rotap sieve shaker. The particle size distribution was found to be in the range of 150 microns to 10 microns.