Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 291-909-3 | CAS number: 90506-47-1
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Melting point / freezing point
Administrative data
Link to relevant study record(s)
- Endpoint:
- melting point/freezing point
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- from 08 march 2018 to 20 september 2018
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- EU Method A.1 (Melting / Freezing Temperature)
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 102 (Melting point / Melting Range)
- Qualifier:
- according to guideline
- Guideline:
- other: ISO 11357-1. (2016). Plastics
- Version / remarks:
- Differential Scanning Calorimetry (DSC) – Part 1: General principles. CEN, Bruxelles.
- Qualifier:
- according to guideline
- Guideline:
- other: ISO 11357-3. (2013). Plastics
- Version / remarks:
- Differential Scanning Calorimetry (DSC) – Part 3: Determination of temperature and enthalpy of melting and crystallization. CEN, Bruxelles.
- GLP compliance:
- yes (incl. QA statement)
- Type of method:
- differential scanning calorimetry
- Specific details on test material used for the study:
- SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: 80555E094
- Expiration date of the lot/batch: 05 December 2018
- Manufacturing test date: 05 December 2017 - Melting / freezing pt.:
- -85.4 °C
- Atm. press.:
- 978 hPa
- Melting / freezing pt.:
- -85 °C
- Atm. press.:
- 977 hPa
- Key result
- Melting / freezing pt.:
- -85.2 °C
- Atm. press.:
- 978 hPa
- Conclusions:
- The melting point of test item was determined using a Differencial Scanning Calorimetry (DSC) and following the OECD Guideline 102, "Melting Point/Melting Range" and the Regulation EC No. 440/2008 Method A.1.
The melting point of the substance was determined to be -85.2 °C at ambient pressure (978.0 hPa). - Executive summary:
In this method, two crucibles were put in the apparatus furnace under inert atmosphere (helium) at atmospheric pressure. One crucible contained the test item, the other was empty and considered as the reference. A specific temperature program was applied.
The crucibles were linked to two thermocouples fixed on the TG-DSC sample carrier. Heat flow differences between the two crucibles and mass variation were recorded on a thermogram.
A cooling system usingliquid nitrogen allowed experiments with low temperatures down to -120°C.
Two trials were conducted and corresponding thermograms were obtained.
The melting point values respect validity criteria (less than 0.5 °C of difference up to 326.85°C) and the melting point of the Indium reference respects the checking cards limits so as its enthalpy.
Reference
Temperature program:
Pre-Study : Peaks assigned to the boiling of the substance were observed and measurement was stopped at 435°C
First determination with Atmospheric pressure 978.0 hPa :
The melting point was observed at -85.4°C (onset temperature of the first peak)
The initial boiling point was observed at 269.1 °C (onset temperature of the second peak) and a corresponding mass loss is observed on the TG curve, showing that all the substance was evaporated at the end of the study.
The crucible was visually checked after the determination: By opening the crucible, no test item left in the crucible and no sign of decomposition was observed.
Second Determination with Atmospheric pressure 977.0 hPa :
The melting point was observed at -85.0°C (onset temperature of the first peak)
The initial boiling point was observed at 269.4 °C (onset temperature of the second peak) and a corresponding mass loss is observed on the TG curve, showing that all the substance was evaporated at the end of the study.
The crucible was visually checked after the determination: By opening the crucible, no test item left in the crucible and no sign of decomposition was observed.
The apparatus is checked with the reference substance Indium.
For temperature, the expected melting point: 156.6 +/- 0.5°C(reference value rounded up due to the temperature resolution of the apparatus used)
Obtained melting point: 156.6°C
The melting point of the Indium respects the defined tolerance of the expected melting point.
For sensitivity, the expected enthalpy: 28.6 +/- 2.9 J/g
Obtained enthalpy: 28.11 J/g
The enthalpy of the indium respects the defined tolerance of the expected enthalpy.
Description of key information
The melting point of test item was determined using a Differencial Scanning Calorimetry (DSC) and following the OECD Guideline 102, "Melting Point/Melting Range" and the Regulation EC No. 440/2008 Method A.1.
The melting point of the substance was determined to be -85.2 °C at ambient pressure (978 hPa).
Key value for chemical safety assessment
- Melting / freezing point at 101 325 Pa:
- -85.2 °C
Additional information
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.