The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
04/2017 to 07/2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
GLP compliance:
yes (incl. QA statement)
Type of method:
effusion method: Knudsen cell
Specific details on test material used for the study:
Name: Iodo(triphenylphosphino)copper
Batch no.: 16060715
Appearance: light yellow powder
Test no.:
#1
Temp.:
20 °C
Vapour pressure:
0 Pa
Test no.:
#2
Temp.:
25 °C
Vapour pressure:
0 Pa
Conclusions:
For the test item Iodo(triphenylphosphino)copper, the following vapour pressures at 20 °C
and at 25 °C were calculated from the regression equation:
Vapour pressure at 20 °C: 4.50 * 10-08Pa
Vapour pressure at 25 °C: 8.88 * 10-08Pa
Executive summary:

Vapour pressure at 20 °C for the test item Iodo(triphenylphosphino)copper: 4.50 * 10-08 Pa.

Description of key information

Vapour pressure at 20 °C for the test item Iodo(triphenylphosphino)copper: 4.50 * 10-08 Pa.

Key value for chemical safety assessment

Vapour pressure:
0 Pa
at the temperature of:
20 °C

Additional information

1x10-6 is the lowest possible value to be processed in EUSES. Therefore, this value is used even if the real vapour pressure is two magnitudes lower.