Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 248-468-7 | CAS number: 27458-90-8
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
![](https://echa.europa.eu/o/diss-blank-theme/images/factsheets/A-REACH/factsheet/print_environmental-fate-and-pathways.png)
Adsorption / desorption
Administrative data
Link to relevant study record(s)
- Endpoint:
- adsorption / desorption: screening
- Type of information:
- experimental study
- Adequacy of study:
- supporting study
- Study period:
- 09-12-2016 to 03-13-2017
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 121 (Estimation of the Adsorption Coefficient (Koc) on Soil and on Sewage Sludge using High Performance Liquid Chromatography (HPLC))
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Type of method:
- HPLC estimation method
- Test temperature:
- 30°C
- Details on study design: HPLC method:
- TEST SYSTEM
The test system consisted of a mass spectrometer fitted with a time of fly mass analyzer and a UV spectrometer placed in series.
UPLC System: Waters UPLC System including binary solvent manager, sample manager, column heater and PDA detector
LCT Premier Mass Spectrometer
Column: Agilent technologies ZORBAX CN 5µm, dim: 2.1 x 150 mm
Column temperature: 30ºC
Mobile phase: Methanol : Water (55.0:45.0 v/v)
pH of mobile phase: 6.6 at 25°C, 6.7 at 30°C
Flow-rate: 0.8 mL/min
Injection volume: 5 µL
UV detector wavelength: 210 nm
DEFINITIVE TEST
The calibration curve was prepared from a reference item stock solution (Formamide, phenanthrene, DDT, acetanilide, methyl benzoate, triadimenol, naphtalene) diluted in methanol. - Key result
- Type:
- log Koc
- Value:
- > 5.63
- pH:
- 6.7
- Temp.:
- 30 °C
- Details on results (HPLC method):
- Using the capacity factor k’ and the partition coefficient log Koc of the reference items, the following calibration curve was obtained:
log Koc = 2.9442 log k’ + 2.2328 r2 = 0.983
The log Koc value for the test item was determined from this equation.
The log Koc value is > 5.63. - Validity criteria fulfilled:
- yes
- Conclusions:
- The definitive test met the validity criteria of the test guideline detailed as follows: the value of log Koc derived from three repeated measurements made under identical conditions and using the same set of reference substances fell within a range of +/- 0.25 log units, the test is thus considered as valid.
The partition coefficient log Koc of the test item is >5.63. - Executive summary:
The definitive test met the validity criteria of the test guideline detailed as follows: the value of log Koc derived from three repeated measurements made under identical conditions and using the same set of reference substances fell within a range of +/- 0.25 log units, the test is thus considered as valid.
The partition coefficient log Koc of the test item is >5.63.
- Endpoint:
- adsorption / desorption: screening
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- June 15, 2010
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- other: see 'Remark'
- Remarks:
- Most of the validity criteria were met, but no reference data were available with results above the obtained value and the purity of the reference substances are not reported. Results for the test substance were extrapolated. GLP-compliant, guideline study. Reliable with restrictions.
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 121 (Estimation of the Adsorption Coefficient (Koc) on Soil and on Sewage Sludge using High Performance Liquid Chromatography (HPLC))
- Deviations:
- yes
- Remarks:
- A reference item with a Koc above the obtained value was not available so the Koc was extrapolated on the basis of the available reference items.
- GLP compliance:
- yes (incl. QA statement)
- Type of method:
- HPLC estimation method
- Media:
- other: cyanopropyl in the stationary phase
- Specific details on test material used for the study:
- Details on properties of test surrogate or analogue material (migrated information):
No data reported - Radiolabelling:
- not specified
- Test temperature:
- 25 +/- 1°C
- Details on study design: HPLC method:
- HPLC using DAD detector and cyanopropyl in the stationary phase and tetrahydrofuran/pure water (55%/45% v/v) in the mobile phase. 10 mg/l each of 7 structurally heterogeneous reference substances from the guidelines, with reported log Kocs, were used to calibrate the elution time. Retention times were recorded after the injection of both separate and mixed reference items. The mixed reference item was injected before and after each of the three injections of test item. Sodium nitrate was also injected three times in order to determine dead time.
- Analytical monitoring:
- no
- Details on sampling:
- No data reported
- Details on matrix:
- No data reported
- Details on test conditions:
- Test item was dissolved in Tetrahydrofuran to a concentration of 1 g/l, and this was further diluted with mobile phase to concentrations of 10 and 100 mg/l.
- Sample No.:
- #1
- Duration:
- 7.653 min
- Initial conc. measured:
- 10 other: mg/L test substance
- Temp.:
- 25 °C
- Sample No.:
- #2
- Duration:
- 7.653 min
- Initial conc. measured:
- 10 other: mg/L test substance
- Temp.:
- 25 °C
- Sample No.:
- #3
- Duration:
- 7.573 min
- Initial conc. measured:
- 10 other: mg/L test substance
- Temp.:
- 25 °C
- Computational methods:
- No data reported
- Type:
- log Koc
- Value:
- 8.5
- Temp.:
- 25 °C
- Remarks on result:
- other: synthetic solid phase used
- Details on results (HPLC method):
- The log Koc of the test item is above the highest value of the reference items (4.09) and was extrapolated to a value of 8.5.
- Transformation products:
- not measured
- Statistics:
- A calibration curve determined from the 7 reference substances was used to determine the adsorption coefficient. Between the log Koc range of 1.25 and 4.09, the linearity of the method was proven. The log Koc of the test item is above the highest value of the reference items (4.09) and was extrapolated to a value of 8.5.
- Validity criteria fulfilled:
- no
- Remarks:
- Most of the validity criteria were met, but no reference data were available with results above the obtained value and the purity of the reference substances were not reported.
- Conclusions:
- The log Koc of the test item is above the highest value of the reference items (4.09) and was extrapolated to a value of 8.5.
- Executive summary:
Mollandin (2010) is a GLP-compliant study following OECD guideline 121. The validity criteria were not met as no reference data were available with results above the obtained value and the purity of the reference substances were not reported. The log Koc of the test substance has therefore been extrapolated. This study is considered reliable and suitable as a key study for this endpoint.
Referenceopen allclose all
Test item results
Measure |
Retention time (min) |
Log k' |
Log Koc |
Average Log Koc |
1 |
11.91 |
1.3233667 |
>5.63 |
>5.63 |
2 |
11.91 |
1.3233667 |
>5.63 |
|
3 |
11.90 |
1.32298457 |
>5.63 |
Sample |
Retention Time (min) | Capacity factor | log K | log Koc |
10mg/l test substance | 7.653 | 6 | 0.78 | 8.5 |
10mg/l test substance | 7.653 | 6 | 0.78 | 8.5 |
10mg/l test substance | 5.573 | 5.93 | 0.77 | 8.4 |
Mean Value | 7.63 | 5.98 | 0.78 | 8.5 |
Reference Item | Retention Time (min) | Log Koc |
Sodium nitrate (dead time) | 1.09 | n.a. |
Acetanilide | 2.86 | 1.25 |
Methylbenzoate | 3.39 | 1.8 |
Triadimenol | 3.39 | 2.4 |
Linuron | 3.39 | 2.59 |
1,2,3-Trichlorobenzene | 3.81 | 3.16 |
Pyrazophos | 4.04 | 3.65 |
Phenanthrene | 4.04 | 4.09 |
Description of key information
The partition coefficient log Koc of di-tert-dodecyl disulfide was determined to be higher than 5.63 in an OECD 117 test. By read-across with di-tert-dodecyl polysulfides, log Koc is considered to be equal to 8.5
Key value for chemical safety assessment
- Koc at 20 °C:
- 316 227 766
Additional information
[LogKoc: 8.5]
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.
![ECHA](/o/diss-blank-theme/images/factsheets/A-REACH/factsheet/echa_logo.png)