Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Guidance on Safe Use

Guidance on Safe Use

Currently viewing:

Administrative data

First-aid measures

Description of first aid measures:
Pay attention to self-protection.
Remove victims from hazardous area. Immediately remove soiled or soaked clothing and remove it to a safe distance. Keep victim warm, in a stabilized position and covered.
Do not leave victims unattended.
If the casualty is unconscious: Place the victim in the recovery position.

Inhalation:
Inhalation is possible if aerosols, mists, dusts, or smoke form.
Move victims into fresh air.
With labored breathing: Provide with oxygen. Consult a doctor.
If the casualty is not breathing: Perform mouth-to-mouth resuscitation, notify emergency physician immediately.

Skin contact:
Wash off affected area immediately with plenty of water for at least 15 minutes.
If symptoms persist, consult a physician for treatment.

Eye contact:
With eye held open, thoroughly rinse immediately with plenty of water for at least 10 minutes.
In case of persistent discomfort: Consult an ophthalmologist.

Ingestion:
Rinse mouth.
Immediately give large quantities of water to drink.
Obtain medical attention.

Most important symptoms and effects, both acute and delayed:
Symptoms:
None known.
Hazards:
Other dangerous properties can not be excluded.

Indication of any immediate medical attention and special treatment needed:
This substance has no remarkable acute health hazard potential. Acute health damage is therefore not to be expected.

Fire-fighting measures

Extinguishing media:
Suitable extinguishing media:
- Water spray jet
- Foam
- Carbon dioxide (CO2)
- Dry powder

Unsuitable extinguishing media:
Do not use a solid water stream as it may scatter and spread fire.

Special hazards arising from the substance or mixture:
Hazard-determining flue gases might develop in case of fire:
- Hydrogen chloride
- Nitrogen oxides (NOx)
- Carbon monoxide
- Carbon dioxide (CO2)

Advice for firefighters:
Contaminated extinguishing water must be treated at a suitable disposal plant in accordance with waste management laws.
Water used to extinguish fire should not enter drainage systems, soil or stretches of water.
Fire residues should be disposed of in accordance with the regulations.
In case of fire, remove the endangered containers and bring to a safe place, if this can be done safely.
Keep out unprotected persons.
In case of fire: wear a self contained respiratory apparatus.
Full protective suit.

Accidental release measures

Personal precautions, protective equipment and emergency procedures:
Keep unauthorized persons away.
Avoid dust formation.
Avoid contact with skin, eyes and clothing.

Environmental precautions:
Observe regulations on prevention of water pollution (check, dam up, cover up).
Do not allow entrance in sewage water, soil, stretches of water, drainage systems, surface water.
If the product contaminates rivers and lakes or drains inform respective authorities.

Methods and material for containment and cleaning up:
Pick up mechanically and collect in a suitable container. Avoid formation of dust.
Pack and label wastes like the pure substance.
Do not detach label from the delivery containers prior to disposal.
Disposal according to local authority regulations.
Clean contaminated surface thoroughly.
To absorb spilled substance an approved industrial vacuum cleaner is recommended.
If necessary, the spilled substance should be moistened.

Handling and storage

Precautions for safe handling:
Decant and handle product in separate areas only, e.g. use glove boxes, cabinets with differential pressure switch etc.
Ensure that apparatus and pipelines are free from leaks.
Do not ventilate into the open.
Dedicated loading/unloading stations required.
Trained personnel must be used.

Conditions for safe storage, including any incompatibilities:
Advice on protection against fire and explosion:
Keep away from combustion sources such as sparks, flames and unprotected light sources.
When using do not smoke.
Take precautionary measures against static charges, keep away from sources of ignition.

Storage:
Store in the original receptacle, keeping this tightly sealed, under cool and dry conditions.

Further information:
In order to ensure due transportation, make certain that stacks are of the correct height, containers are securely fastened so as not to fall off, and labelled according to the regulations.

German storage class:
4.2 - Pyrophoric and self-heating hazardous materials.

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
UN 3088
Shippingopen allclose all
Labels:
4.2
SpecialProvisionsopen allclose all

Inland waterway transport (UN RTDG/ADN(R))

UN number:
UN 3088
Shippingopen allclose all
Labels:
4.2
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
UN 3088
Shipping information
Proper shipping name and description:
SELF-HEATING SOLID, ORGANIC, N.O.S. (7-Chloro-5-(2-chlorophenyl)-1,3-dihydro-3-acetoxy-2H-1,4-benzodiazepin-2-one)
Chemical name:
7-Chloro-5-(2-chlorophenyl)-1,3-dihydro-3-acetoxy-2H-1,4-benzodiazepin-2-one
Labels:
4.2
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
UN 3088
Shipping information
Proper shipping name and description:
Self-heating solid, organic, n.o.s. (7-Chloro-5-(2-chlorophenyl)-1,3-dihydro-3-acetoxy-2H-1,4-benzodiazepin-2-one)
Chemical name:
7-Chloro-5-(2-chlorophenyl)-1,3-dihydro-3-acetoxy-2H-1,4-benzodiazepin-2-one
Labels:
4.2
Remarksopen allclose all

Additional transport information

Additional information
Special provisions / remarks / other:
Loading instructions/Remarks:
IATA_C: ERG-Code 4L
IATA_P: ERG-Code 4L
IMDG: On deck only.

Combination traffic :
Labelling of containers / shipping units following main product run as per sea or air transport regulations.

Exposure controls / personal protection

Control parameters:
Other information:
Contains no substances with occupational exposure limit values.

DNEL/DMEL values:
Remarks: No substance-related safety assessment is necessary / has been conducted for this product.

PNEC values:
Remarks: No substance-related safety assessment is necessary / has been conducted for this product.

Exposure controls:
Engineering measures:
Decant and handle product in separate areas only, e.g. use glove boxes, cabinets with differential pressure switch etc.
Do not lead exhaust air back to workplace areas unfiltered.
Exhaust filter or scrubber.
Exhaust air filter (HEPA-filter).
Do not add wastewater to a biological wastewater treatment plant.
All precautionary measures indicated have to be observed.
Provide for installation of emergency shower and eye bath.

Exposure controls:
Minimisation of emissions by means of suitable technical measures such as flanges and valves with low leakage rates, recirculation of vapours.
The substance must be handled under strictly controlled conditions in accordance with Article 17/18 of the REACH regulation.

Personal protective equipment:
Respiratory protection:
If dust occurs: Respirator with P3 particle filter.
Accidental release measures:
In the case of respirable dust, use self-contained breathing apparatus.
Note time limit for wearing respiratory protective equipment.

Hand protection:
Glove material: Nitrile, for example, Dermatril 740, Kächele-Cama Latex GmbH (KCL), Germany
Material thickness: 0.11 mm
Method: DIN EN 374
Accidental release measures:
Glove material: Nitrile/Chloroprene, for example, Nitopren 717, Kächele-Cama Latex GmbH (KCL), Germany
Material thickness: 0.65 mm
Method: DIN EN 374.
Selection of protective gloves to meet the requirements of specific workplaces.
Suitability for specific workplaces should be clarified with protective glove manufacturers.
The information is based on our own tests, references from the literature and information from glove manufacturers, or derived by analogy with similar materials.
Remember that the useful time per day of a chemical protection glove may be much shorter than the permeation time determined according to EN 374 due to the many different influential factors involved (e.g. temperature).

Eye protection:
Safety glasses with side-shields conforming to EN166.
Accidental release measures:
Close-fitting protective goggles (e.g. closed goggles).

Skin and body protection:
Select materials and equipment for physical protection depending on the concentration and volume of hazardous substances and the workplace involved.

Hygiene measures:
Do not eat, drink, smoke, or sniff while at work. Wash your hands and/or face before breaks and before termination of work.
Take off clothing and shoes contaminated with product. Clean before reuse.
Preventive skin protection is recommended.
Use barrier cream regularly.
Cleanse and apply cream to skin after work.

Protective measures:
All precautionary measures indicated have to be observed.
Risk assessment and risk monitoring of all work places required.
Health, Safety and Emergency Management System recommended.
Regular safety training is a must.
Written approval necessary in case of non-routine jobs, e.g. maintenance activities.

Environmental exposure controls:
In some cases, exhaust air scrubbers, filters or technical changes to the processing plant will be required in order to decrease emissions to acceptable values.

Stability and reactivity

Reactivity:
No further information available.

Chemical stability:
No further information available.

Possibility of hazardous reactions:
No dangerous reaction known under conditions of normal use.

Conditions to avoid:
No decomposition if used as directed.
Take precautionary measures against static discharges.
Avoid shock and friction.

Incompatible materials:
No further information available.

Hazardous decomposition products:
No hazardous decomposition products known.

Disposal considerations

Waste treatment methods:
Product:
Strictly controlled conditions during disposal or treatment to air, wastewater and waste.
Do not add wastewater to a biological wastewater treatment plant
Bring used exhaust air filter for incineration
Disposal according to local authority regulations.

Uncleaned packaging:
Do not reuse empty containers and dispose of in accordance with the regulations issued by the appropriate local authorities.

Waste Key Number:
The waste key number must be determined as per the European Waste Types List (decision on EU Waste Types List 2000/532/EC) in cooperation with the disposal firm / producing firm / official authority.