Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Endpoint:
flash point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Guideline study with acceptable restrictions

Data source

Reference
Reference Type:
other company data
Title:
Unnamed
Year:
2014

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
ISO No., other: Annex V, A9 (Pensky-Martens, DIN 51758)
GLP compliance:
yes
Type of method:
closed cup

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Flash point
Flash point:
95 °C
Remarks on result:
other: pressure is not provided in the inquiry result form ECHA

Applicant's summary and conclusion