Registration Dossier

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)

Data source

Reference
Reference Type:
other: Body responsible for the test
Title:
Unnamed
Year:
1992
Report Date:
1992

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
other: ec a.4 (Static method)
GLP compliance:
yes
Type of method:
static method

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Vapour pressureopen allclose all
Temp.:
20 °C
Vapour pressure:
0.037 Pa
Remarks on result:
other: First vapour perssure
Temp.:
50 °C
Vapour pressure:
0.26 Pa
Remarks on result:
other: Second vapour pressure
Temp.:
25 °C
Vapour pressure:
0.051 Pa
Remarks on result:
other: Estimated vapour pressure value

Applicant's summary and conclusion