Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
17 February 2009 - 14 April 2009
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study has been performed according to OECD and EC guidelines and according to GLP principles

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2009
Report date:
2009

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: BS ISO 13320-1:1999
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of distribution:
other: laser diffraction particle size analysis

Test material

Constituent 1
Details on test material:
- Name of test material (as cited in study report): Custom Red #2
- Substance type: Violet powder
- Physical state: Solid
- Lot/batch No.: C50APR0805D
- Expiration date of the lot/batch: 08 January 2010
- Stability under test conditions: Stable
- Storage condition of test material: At room temperature in the dark

Results and discussion

Particle sizeopen allclose all
Percentile:
D50
Mean:
12.307 µm
Remarks on result:
other: Migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.
Percentile:
D10
Mean:
< 4.134 µm
St. dev.:
0.107
Percentile:
D50
Mean:
< 12.307 µm
St. dev.:
0.267
Percentile:
D90
Mean:
< 27.943 µm
St. dev.:
1.519

Applicant's summary and conclusion

Conclusions:
Using the Dry Powder Module, the laser diffraction test conducted to determine the particle size analysis produced the following results (in average µm):

Volume weighted mean: 16.649
Median (d.50): 12.307
Mode: 13.686
MMAD (Mass Median Aerodynamic Diameter): 13.082
10% of material is < 4.134
50% of material is < 12.307
90% of material is < 27.943