Registration Dossier

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
28.10.2005-06.03.2006
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: The study was conducted according to EU guidelines and GLP principles.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2006
Report Date:
2006

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.4 (Vapour Pressure)
GLP compliance:
yes
Type of method:
effusion method: vapour pressure balance

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Vapour pressureopen allclose all
Temp.:
20 °C
Vapour pressure:
8.1 other: *10-6Pa
Temp.:
25 °C
Vapour pressure:
1.8 other: *10-5Pa
Temp.:
50 °C
Vapour pressure:
6.9 other: *10-4Pa

Applicant's summary and conclusion

Conclusions:
The vapour pressure of CCP-V2-1 at 20°C is 8.1*10-6 Pa.
Executive summary: