Registration Dossier

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
13.-22.10.1997
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: The study was conducted according to EU guidelines and GLP principles.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1997
Report Date:
1997

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
yes

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Pyrophoric solids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.
Pyrophoric liquids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.

Any other information on results incl. tables

During the heating-phase of the pre-test the substance started to melt, but showed no ignition.Therefore, no main test was conducted.

Applicant's summary and conclusion

Interpretation of results:
non flammable
Remarks:
Migrated information
Conclusions:
CCP-V2-1 is not flammable.
Executive summary:

The flammability of CCP-V2 -1 was tested according to EU-method A.10. CCP-V2 -1 showed no flammability.