Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
from 8 August 2022 to 26 September 2022
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2022
Report date:
2022

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus

Test material

Constituent 1
Chemical structure
Reference substance name:
1-isopropyl-3-(prop-1-en-2-yl)benzene
EC Number:
924-469-4
Cas Number:
1129-29-9
Molecular formula:
C12H16
IUPAC Name:
1-isopropyl-3-(prop-1-en-2-yl)benzene
Test material form:
liquid

Results and discussion

Flash point
Key result
Flash point:
86.5 °C
Atm. press.:
ca. 101 325 Pa

Any other information on results incl. tables

The result of the pre-test (expected flash point, not to ISO 2719): 77.0°C
The results of the main tests are:


First determination: Flash point, corrected for atmospheric pressure: 87.0°C
Second determination: Flash point, corrected for atmospheric pressure: 86.0°C

As the results of the two determinations were in agreement within the requirement (the results do not differ by more than 2.0 °C), another determination wasn't performed.


 

Applicant's summary and conclusion

Interpretation of results:
Category 3 (flammable liquids) based on GHS criteria
Conclusions:
The flash point of the test substance was determined to be equal to 86.5°C
Executive summary:

Using the method that complies with the requirements of the ISO standard 2719:2016: Determination of flash point - Pensky-Martens closed cup method.


The flash point of the test substance was determined to be equal to 86.5°C