Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
pH
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2020-12-02
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2020
Report date:
2020

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7000 (pH)
Version / remarks:
1996
Deviations:
no
Qualifier:
according to guideline
Guideline:
CIPAC MT 75 (Determination of pH Values)
Version / remarks:
2000
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
Chloroacetone
EC Number:
201-161-1
EC Name:
Chloroacetone
Cas Number:
78-95-5
Molecular formula:
C3H5ClO
IUPAC Name:
chloroacetone

Reagents

Reagent:
water

Results and discussion

pH value
Key result
pH value:
5.27
Temp.:
20.9 °C
Concentration:
1 vol%

Any other information on results incl. tables

The temperature of the buffer solutions for calibration of the pH meter was in the range of 20.3 to 20.4 °C. The pH values of two replicates of a 1 % test item after 1 and 10 minutes is shown in the table.

Replicate

1 min

10 min

pH

T / °C

pH

T / °C

1

7.398

21.0

5.811

21.1

2

5.680

20.7

4.738

20.6

Mean

6.54

20.9

5.27

20.9

Applicant's summary and conclusion

Conclusions:
The pH value of the test item was determined to be 5.27.
Executive summary:

An experimental study was conducted to determine the pH value of the test item according to CIPAC Method MT 75.3 and EPA OPPTS 830.7000. Therefore, a 1 %(v/v) aqueous solution of the test item was prepared. Two replicates were tested after 1 min and 10 min. The mean pH value of the test item solution after 10 min was determined to be 5.27.