Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
relative self-ignition temperature (solids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
September 21, 1992 - September 22, 1992
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1992
Report date:
1992

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.16 (Relative Self-Ignition Temperature for Solids)
Version / remarks:
1984
Deviations:
no
GLP compliance:
yes

Test material

Constituent 1
Reference substance name:
2,4-bis[N'-(4-methylphenyl)ureido]toluene
EC Number:
411-790-5
EC Name:
2,4-bis[N'-(4-methylphenyl)ureido]toluene
Cas Number:
54390-87-3
Molecular formula:
C23H24N4O2, C24H34N4O2
IUPAC Name:
3-(2-methyl-3-{[(4-methylphenyl)carbamoyl]amino}phenyl)-1-(4-methylphenyl)urea; 3-(2-methyl-5-{[(4-methylphenyl)carbamoyl]amino}phenyl)-1-(4-methylphenyl)urea; 3-{2-methyl-3-[(octylcarbamoyl)amino]phenyl}-1-(4-methylphenyl)urea
Test material form:
solid: particulate/powder
Details on test material:
- Name of test material (as cited in study report): KY-MA
- Lot/batch No.: 4HT059M
- Expiration date of the lot/batch: August 5, 1994
- Physical state: Light yellow solid
- Storage condition of test material: At room temperature in the dark
Specific details on test material used for the study:
At temperatures above 180°C the substance evaporates, reacts and/or decomposes.

Results and discussion

Relative self-ignition temperature (solids)
Remarks on result:
no self ignition observed under the test conditions

Any other information on results incl. tables

Run time experiment [min]

Oven temperature [°C]

Sample temperature [°C]

0

35

35

100

80

80

200

125

125

300

170

170

400

220

220

500

265

265

524

280

280

532

280

340

538

285

290

600

320

325

700

370

370

760

400

400

- The test substance showed an exothermic reaction, starting at an oven temperature of approx. 280°C and reached a maximum temperature of 340°C.

- The test substance did not reach 400°C by self-ignition

Applicant's summary and conclusion

Conclusions:
No self-ignition took place up to 400°C.
Executive summary:

In a GLP study performed according to EC A.16, using a temperature programmed laboratory oven, a stainless steel wire mesh cube, NiCr/NiAl thermocouples and a temperature recording device, no self-ignition took place up to 400°C.