Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From 07 August 2018 to 09 August 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Remarks:
GLP study performed in accordance with international guidelines
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.6315 (Flammability)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 3679 (Determination of flash point - Rapid equilibrium closed cup method)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ASTM D3278 (Standard test methods for flash point of liquids by small scale closed-cup apparatus)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Remarks:
Date of Inspection: 18 July 2017 - 20 July 2017 Date on Certificate: 28 November 2017
Type of method:
equilibrium method closed cup
Flash point apparatus:
Setaflash apparatus
Dynamic viscosity of test material:
The dynamic visosity of test material was not reported.
Key result
Flash point:
158.1 °C
Atm. press.:
100.8 kPa

Results of the flash point determination are shown in the following table:

Table 1

Temperature (°C)

Observations

22.0

No flash

27.0

No flash

32.0

No flash

37.0

No flash

42.0

No flash

47.0

No flash

52.0

No flash

57.0

No flash

62.0

No flash

67.0

No flash

72.0

No flash

72.0 (fresh sample)

No flash

77.0

No flash

82.0

No flash

87.0

No flash

92.0

No flash

97.0

No flash

102.0 (fresh sample)

No flash

107.0

No flash

112.0

No flash

117.0

No flash

122.0

No flash

127.0

No flash

132.0

No flash

137.0

No flash

142.0

No flash

147.0

No flash

152.0

No flash

157.0

No flash

162.0

A blue flash spread across the sample cup

162.0 (fresh sample)

A blue flash spread across the sample cup

157.0 (fresh sample)

No flash

158.0 (fresh sample)

A blue flash spread across the sample cup

158.0 (fresh sample)

A blue flash spread across the sample cup

156.0 (fresh sample)

No flash

156.0 (fresh sample)

No flash

Atmospheric pressure: 100.8 kPa

Observed flash point: 158 °C

Corrected flash point: 158.1 °C

Interpretation of results:
GHS criteria not met
Conclusions:
The flash point of the test item has been determined to be 158 ± 2 °C.
Executive summary:

The flash point of the test item was determined to be 158 ± 2 °C, using a closed cup equilibrium method designed to be compatible with Method A.9 Flash Point of Commission Regulation (EC) No 440/2008 of 30 May 2008.

Description of key information

The flash point of the test item was determined to be 158 ± 2 °C. The test item is therefore considered to be non-flammable.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
158 °C

Additional information

The flash point of the test item was determined to be 158 ± 2 °C, using a closed cup equilibrium method designed to be compatible with Method A.9 Flash Point of Commission Regulation (EC) No 440/2008 of 30 May 2008.