Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
05 Dec 2016 (experimental starting date) - 20 Feb 2017 (experimental completion date)
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
comparable to guideline study
Qualifier:
equivalent or similar to guideline
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
30 May 2008
Principles of method if other than guideline:
Anon (1989) Flash Point of Liquids by Setaflash Closed-Cup Apparatus, ASTM D-3278-89, P1-7
GLP compliance:
yes (incl. QA statement)
Type of method:
equilibrium method
Flash point apparatus:
Setaflash apparatus
Remarks:
Setaflash 30000-0 flash point tester
Flash point:
44.39 °C
Atm. press.:
99.6 kPa
Remarks on result:
other:
Remarks:
44.0 ± 2 °C
Interpretation of results:
Category 3 (flammable liquids) based on GHS criteria
Conclusions:
The flash point of the test item has been determined to be 44.0 ± 2 °C.
Executive summary:

The flash point of the test item has been determined to be 44.0 ± 2 °C.

Description of key information

The flash point of the test item has been determined to be 44.0 ± 2 °C.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
44.39 °C

Additional information