Registration Dossier

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
07.09.15 - 06.06.16
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
GLP compliance:
no
Type of method:
effusion method: vapour pressure balance
Temp.:
20 °C
Vapour pressure:
< 0 Pa
Key result
Temp.:
25 °C
Vapour pressure:
< 0 Pa
Temp.:
50 °C
Vapour pressure:
< 0.003 Pa
Executive summary:

The test item had a vapour pressure of <1.6*10 -4 Pa at 25°C.

Description of key information

Key value for chemical safety assessment

Vapour pressure:
0 Pa
at the temperature of:
25 °C

Additional information